Do you have a question about the Lainox NABOO NAEV071 and is the answer not in the manual?
Requirements for room ventilation, openings for gas installations, and compliance with specific regulations.
Requirement for a flue gas extraction stack or system, and checking for special authorization for flue gas emission.
Mandate for a multiple pole main isolating switch with a minimum contact gap of 3 mm on each pole.
Oven has type Y attachment; installer provides cable and hardware, adhering to 'General data' table.
Connecting to an equipotential system via a 10 mm² conductor to the marked terminal.
Water characteristics must meet limits for hardness, pH, and chlorides to prevent corrosion and scaling.
Description of the CALOUT cleaning system for keeping the steam generator free from limescale.
Choosing gas pipe section based on gas type and consumption, and connection methods.
Procedure for measuring inlet pressure using a manometer connected to the gas adjustment valve.
Performing combustion checks for CO and CO2 values using an appropriate instrument.