EasyManua.ls Logo

Lainox NABOO NAEB071

Lainox NABOO NAEB071
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
90027911rev04
EN
CAUTION: Read the instructions
prior to using the equipment
INSTALLATION AND
MAINTENANCE MANUAL
NABOO
SAPIENS
AROMA NABOO
AROMA SAPIENS
Question and Answer IconNeed help?

Do you have a question about the Lainox NABOO NAEB071 and is the answer not in the manual?

Lainox NABOO NAEB071 Specifications

General IconGeneral
BrandLainox
ModelNABOO NAEB071
CategoryOven
LanguageEnglish

Summary

3. SPECIAL REQUIREMENTS FOR THE INSTALLATION SITE

Ventilation and Gas Safety

Room ventilation, openings for gas installations, and flue gas extraction.

Gas Supply and Control Placement

Gas plumbing regulations, shutoff valve installation, and placement of control valves.

5. POSITIONING

Lifting and Handling Procedures

Safe lifting techniques using forklifts or pallet jacks, and unpacking.

6. ELECTRICAL CONNECTIONS AND EQUIPOTENTIAL BONDING

Type Y Attachment and Isolation Switch

Requirements for type Y attachment, installer-provided cable, and main isolating switch.

Wiring and Earth Connection Safety

Accessing terminal board, wiring, and ensuring earth wire length for safety.

Equipotential Bonding System

Connecting to the equipotential system for building earth bonding and electrical safety.

7. POINTS TO REMEMBER WHEN MAKING THE ELECTRICAL CONNECTION

Fan Motor and Neutral Pin Checks

Verifying fan motor rotation, balance, and correct neutral pin connection.

8. WATER AND DRAIN CONNECTIONS

9. WASHING SYSTEMS

10. CALOUT (if present)

The CALOUT Cleaning System

Description of the CALOUT system for steam generators and its product usage guidelines.

12. GAS CONNECTION PROCEDURES

Gas Connection and Leak Testing

Gas connection requirements, pipe sizing, shutoff valve, and leak test methods.

13. OPERATING AT THE RATED HEAT OUTPUT

Gas Type, Inlet Pressure, and Commissioning

Appliance gas conversion, commissioning requirements, and acceptable inlet pressure ranges.

Burner Testing and Speed Adjustment

Testing burner ignition, minimum, and maximum speeds, and adjusting operating values.

Combustion Analysis and Gas Conversion Procedures

Measuring CO/CO2 values, checking ranges, and procedures for gas type conversion.

14. COMMISSIONING AND TESTING

Pre-Installation and Connection Checks

Verifying installation integrity, protective film, vents, connections, safety, and leak checks.

17. INSTALLATION DIAGRAMS

Related product manuals