Do you have a question about the Lainox AROMA NABOO AREN064 and is the answer not in the manual?
Model | AROMA NABOO AREN064 |
---|---|
Category | Oven |
Temperature Range | 30 °C - 300 °C |
Control Type | Touchscreen |
Type | Combination oven |
Power Supply | 400V 3N~ |
Requirements for connecting the oven (Type Y attachment) to the power supply using qualified hardware.
Requirement to connect the oven to an equipotential system using a 10 mm² conductor.
Electrical safety is guaranteed only when connected correctly to an efficient earth system.
Details on water hookup for steam generators and vaporizers, including requirements for softened water and hose compliance.
Required water characteristics (hardness, pH, chlorides) to prevent corrosion and scaling.
Requirements for draining water, including pipe specifications, length, angle, and temperature.
Instructions for positioning and setting the COMBICLEAN detergent cartridge/container for countertop and floor models.
Instructions for positioning and setting the CALFREE descaler cartridge/container for countertop and floor models.
Procedure for replacing the COMBICLEAN detergent cartridge for countertop and floor-standing models.
Procedure for replacing the CALFREE descaler cartridge/tank for countertop and floor-standing models.
Instructions for positioning and setting COMBICLEAN detergent and CALFREE descaler cartridges/containers.
Instructions for creating detergent/descaler using the 'Generate SolidClean' icon via the Naboo settings.
Explanation of the CALOUT cleaning system for keeping the steam generator free from limescale.
Instructions for installing ovens with the CALOUT device, including tank placement and hose connection.
Guidelines for choosing gas supply pipe section, designing the system, and connection types.
Procedure for testing gas connections for leaks using spray or foamy liquid, and a warning against using naked flames.
Information on flue gas exhaustion for different installation types (A3, B13, B23) and associated warnings.
Procedure for checking nominal heat capacity, including chamber burner settings and management screen access.
Guidance on checking combustion values (CO, CO2), gas conversion, and boiler burner operations.
Checklist for initial appliance and installation checks, including protective film, vents, connections, safety, leaks, and drainage.
Instruction to light the oven and check smooth burner ignition.
Method to ensure correct operation by measuring gas consumption and comparing with technical data.