WARNING! This set contains chemicals that may be harmful
if misused. Read cautions on individual containers carefully.
Not to be used by children except under adult supervision.
Color
Q
Pro-11
7/09 62058-V2
PO Box 329 Chestertown Maryland 21620 USA
800-344-3100 410-778-3100 410-778-6394
www.lamotte.com
Order Code 2058
!
!
!
!
!
Insert tubes into ColorQ with line and arrow facing forward.
If unit should auto-off during testing rinse and fill one tube to Blank and return
to testing.
Replace reagent caps securely.
Use only LaMotte replacement reagents.
= Shade meter from bright sunlight. Press/Hold button to turn off.
Brush and rinse all tubes promptly after use.
Allow tubes to dry before returning to case.
!
!
s
Eng
!
!
!
!
!
!
!
Introduire le ColorQ droit.
= Maintenir l’appareil à l’ombre.
Appuyer le bouton off pour l’eteindre.
Si l'appareil s'éteint automatiquement refaire
un blanc et reprendre l'analyse.
Essuyer et nettoyer tous les tubes
correctement après l'usage.
Permettre que les tubes se sechent bien
avant de les réutiliser.
Ferrer correctement les reactifs.
Utilisez des réactifs LaMotte pour rechanger
uniquement.
s
Fr
!
!
!
!
!
!
Insertar el tubo en el ColorQ recto.
= apartar el aparato de los rayos del sol. Presionar/mantener el botón
para apagar.
Si el aparato se auto-apaga durante el test, llenar un tubo para el Blanco y
volver al análisis.
Enjuagar y limpiar todos los tubos adecuadamente después del uso.
Permitir que los tubos se sequen antes de volver a usarlos.
Cerrar correctamente los reactivos.
s
Es
For software version 2.00 or higher
Question and Answer IconNeed help?

Do you have a question about the LaMotte ColorQ Pro-11 and is the answer not in the manual?

LaMotte ColorQ Pro-11 Specifications

General IconGeneral
BrandLaMotte
ModelColorQ Pro-11
CategoryMeasuring Instruments
LanguageEnglish

Summary

ColorQ Pro-11 Operation Guide

General Safety and Usage Precautions

Key safety guidelines and important usage notes for the ColorQ Pro-11.

Blank Calibration Procedure

Steps for performing the blank calibration on the ColorQ meter.

Free Chlorine and Bromine Testing

Instructions for measuring Free Chlorine and Bromine levels with ColorQ.

Total Chlorine Measurement

Procedure for determining Total Chlorine concentration using ColorQ.

pH Level Testing

How to test the pH of water samples with the ColorQ system.

Total Alkalinity Determination

Steps to measure Total Alkalinity accurately with the ColorQ meter.

Calcium Hardness Analysis

Guide for testing Calcium Hardness in water samples using ColorQ.

Cyanuric Acid Measurement

Procedure for testing Cyanuric Acid (stabilizer) levels.

Copper Concentration Test

How to measure Copper levels in water with the ColorQ device.

Iron Level Testing

Steps for conducting Iron tests using the ColorQ water quality meter.

Biguanide Level Measurement

Procedure for measuring Biguanide levels in water with ColorQ.

Biguanide Shock (Peroxide) Test

How to test for Biguanide Shock (Peroxide) using the ColorQ.

Related product manuals