QUICK START GUIDE
TESTING
1. Press and hold until the meter turns on.
2. Tap . Select a Water Source type. Tap to confirm.
3. Tap . Select a disk series (found on disk packaging). Tap
to confirm.
NOTE: Disk Series are limited by Water Source Type selection.
4. Remove a disk from the packaging.
5. Use the syringe (1189) to fill the disk with the water sample.
6. Insert the disk. Cover the disk with the Universal Disk Cover
(1719). Close the lid.
7. Tap to start test. Tap to stop the test. If the test is
cancelled discard the disk.
8. The results will be displayed.
9. Choose an option.
¬ Tap to add a tag.
¬ Tap the highlighted to save the test results to the
test log if Auto Save is not enabled.
¬ Tap the hightlighted to send the results to the
enabled Mobile Bluetooth Printer.
¬ Tap the highlighted to send the results to a
Bluetooth enabled device.
¬ Tap to return to the Test Screen.
10. Press and hold for 2 seconds to turn the meter off.
DOS & DON’TS
BEFORE FIRST USE
¬ Fully charge battery using the Spin Touch
USB cable and adapter plug in AC outlet.
¬ Ensure your Spin Touch has latest
firmware. A USB connection to a
Windows® PC is required:
1. Download and install WaterLink
Connect 2 Application for Windows at
http://softwarecenter.lamotte.com/.
Select WaterLink Connect 2 Software
for Windows FREE Download.
2. Plug meter into the computer with
the provided USB cable and launch
WaterLink Connect 2 Application from
the Start Menu.
3. A prompt will appear if firmware
updates are available. Select Update.
Testing and data transfer will not
be possible until firmware has been
updated.
NOTE: For water samples over 100 °F (38 °C) subtract
0.3 from pH result or, for the most accurate result,
wait until water sample is below 90 °F (32 °C) to test.
Remove residue daily. Residue will damage the meter
and cause inaccurate results. See Cleaning in manual.
¬ Do not touch top or bottom of disk. Handle disk by the
edge.
¬ Do not fill disk while in the meter. Fill disk on clean, dry
surface.
¬ Fill the disk on a dark surface to more easily see the
sample water.
¬ The disk should not contain any large air bubbles. Air
bubbles will result in erroneous results.
¬ Always use the disk cover.
¬ Only the Universal Disk Cover (Code 1719) can be used
with the WaterLink Spin Touch.
¬ Empty syringe of old sample before filling with next
sample.
¬ Remove filled disk from meter after testing. Do not
travel with filled disks in meter. They may leak.
¬ Keep the chamber clean and dry. Gently swab LED
and photodiode lenses located around the hub with
a cotton swab dampened with streak-free window
cleaner. Do not use alcohol. It will leave a thin film over
the lenses when dry.
¬ Go to SETTINGS>Other Settings to select hardness and
nitrogen units. Nitrogen results can be reported in ppm
Nitrate-N units or ppm Nitrate units. 1 Nitrate-N unit =
4.4 Nitrate units.

Other manuals for LaMotte WaterLink SpinTouch DW

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LaMotte WaterLink SpinTouch DW and is the answer not in the manual?

LaMotte WaterLink SpinTouch DW Specifications

General IconGeneral
DisplayColor Touchscreen
ConnectivityBluetooth, USB
PowerRechargeable lithium-ion battery
Measurement ParametersFree Chlorine, Total Chlorine, pH, Cyanuric Acid, Copper, Iron, Nitrate
Testing Time60 seconds per test
Resolution0.1 pH
MemoryStores test data

Related product manuals