TROUBLE CAUSE REMEDY
Compressor does not start (no
hum), but gas cooler fan motor
runs.
1. Compressor relay capacitors or overload
malfunctioning.
2. Inadequate voltage.
3. Incorrect wiring.
4. Compressor malfunctioning.
1. Replace compressor relay capacitors or
overload.
2. Measure voltage across common and run
terminal on compressor. Voltage must not
drop below 90% of rated voltage.
3. Refer to wiring diagram and correct.
4. Have the unit repaired by a qualied
service technician.
Compressor does not start but
hums.
1. Inadequate voltage.
2. Incorrect wiring.
3. Starting relay capacitors malfunctioning.
4. Compressor malfunctioning.
1. Measure voltage across common and run
terminal on compressor. Voltage must not
drop below 90% of rated voltage.
2. Refer to wiring diagram and correct.
3. Replace starting relay or capacitors. Be
sure to use correct rating. Failure to use
correct rating will cause compressor
failure.
4. Have the unit repaired by a qualied
service technician.
Compressor starts but does not
switch o󰀨 start winding (will run
for only a few seconds before
internal overload switches com-
pressor o󰀨).
1. Inadequate voltage.
2. Incorrect wiring.
3. Starting relay malfunctioning.
1. Measure voltage across common and run
terminal on compressor. Voltage must not
drop below 90% of rated voltage.
2. Refer to wiring diagram and correct.
3. Replace starting relay. Be sure to use
correct relay. Failure to use correct relay
will cause compressor failure.
Compressor starts and runs
a short time but shuts o󰀨 on
overload.
1. Dirty condenser.
2. Insu󰀩cient or blocked air ow.
3. Inadequate voltage.
4. Incorrect wiring.
5. Defective condenser fan motor.
1. Clean the condenser.
2. Remove all obstruction and allow for mini-
mum clearances of 15 inches (203 mm)
over top.
3. Measure voltage across common and run
terminal on compressor. Voltage must not
drop below 90% of rated voltage.
4. Refer to wiring diagram and correct.
5. Have the unit repaired by a qualied
service technician.
Compressor runs normally, but
water line is frozen.
1. Low water level in water bath.
2. Syrup in water bath.
3. Water cage is out of position.
4. Low refrigerant charge or slow refrigerant
leak.
1. Add water to water bath until water runs
out of overflow into drip tray.
2. Drain water from water bath and refill with
clean water.
3. Reposition water cage.
4. Find and repair leak. Recharge system.
Compressor cycles on and o󰀨
frequently during the initial
pulldown and/or normal
operations.
1. PCB malfunctioning.
2. Defective probe.
3. Weak overload or pressure switch.
1. Have the unit repaired by a qualied
service technician.
2. Replace probe.
3. Have the unit repaired by a qualied
service technician.