SPECIFICATIONS
1500 POSTMIX
DIMENSIONS
Width 19 3/16 inches (48.74 cm)
Depth 24 inches (60.96 cm)
Height (without legs) 25 3/8 inches (64.45 cm)
WEIGHT
Shipping 150 pounds (68.2 kg)
Empty 130 pounds (59.0 kg)
Operating 220 pounds (99.8 kg)
ICE BANK WEIGHT 30 pounds (13.6 kg)
WATER BATH CAPACITY 12 gallons (45.4 liters)
COMPRESSOR 1/3 HP, Tecumseh, 115V/60Hz
AGITATOR MOTOR 25 W, 115V
CONDENSER MOTOR 9 W, 115V
ICE BANK CONTROL Lancer Electronic Ice Bank Control (EIBC)
TRANSFORMER Basler, 115V (Primary)/24V (Secondary)
OPTIONS 230V/50Hz and 240V/60Hz systems available
DRINK CAPACITY
395 - 12 ounce (354.8 ml) drinks under 40°F (4.4°C) at four (4) drinks per minute with 75°F (23.9°C)
ambient inlet water and syrup.
INSTALLATION AND SERVICE MANUAL
FOR LANCER DISPENSERS
SERIES 1500 POSTMIX
SERIES 1500E POSTMIX
SERIES 1500 PREMIX
REV. 02/11/00
P.N. 28-0450
This is an initial manual release.
FAX ENGINEERING: 210-310-7096
"Lancer" is the registered trademark of Lancer Copyright — 2000 by Lancer, all rights reserved.
25 3/8 "
64.45 cm
18 3/4 "
47.63 cm
24 "
60.96 cm
19 3/16 "
48.74 cm
9 1/2 "
24.13 cm
3 1/2 "
8.89 cm
Please refer to the Lancer web site (www.lancercorp.com) for
information relating to Lancer Installation and Service Manuals,
Instruction Sheets, Technical Bulletins, Service Bulletins, etc.
6655 LANCER BLVD. • SAN ANTONIO, TEXAS 78219 USA • (210) 310-7000
FAX SALES
• NORTH AMERICA – 210-310-7245 • INTERNATIONAL SALES – 210-310-7242 • CUSTOMER SERVICE – 210-310-7242 •
• LATIN AMERICA – 210-310-7245 • EUROPE – 32-2-755-2399 • PACIFIC – 61-8-8268-1978 •

Table of Contents

Questions and Answers

  • S
    shelley10Sep 12, 2025
    Why is my lancer 1500 POSTMIX Dispenser dispensing only water or only syrup?
    • S
      sheila93Sep 12, 2025
      If your Lancer Dispenser is dispensing only water or only syrup, the most likely cause is: * The water or syrup shutoff on the mounting block is not fully open. Open the shutoff fully.
  • B
    brittanygreenAug 25, 2025
    How to fix warm drinks from lancer 1500 POSTMIX?
    • K
      Kendra KeyAug 25, 2025
      If your Lancer Dispenser is dispensing warm drinks, consider the following: * Check for restricted airflow around the sides, top, and inlet of the unit. Remove any obstructions blocking airflow through the grill. * Ensure the dispenser is connected to a cold water supply, not a hot water supply. * There may be a refrigerant leak. In that case you should repair and recharge the system. * The condenser fan motor may not be working, consider replacing it. * The condenser might be dirty, so clean it. * You may have exceeded the dispenser's capacity, in that case add a pre-cooler.
  • B
    butlerjulieAug 26, 2025
    What to do if there is insufficient syrup flow in my Lancer Dispenser?
    • O
      Olivia CampbellAug 27, 2025
      If you're experiencing insufficient syrup flow in your Lancer Dispenser, check these potential causes: * Insufficient CO2 pressure to the BIB pumps. Adjust the CO2 pressure to 80 PSI (minimum 70 PSI) for BIB pumps. * The shutoff on the mounting block is not fully open. Open it fully. * Foreign debris in the syrup flow control. Remove the syrup flow control from the upper body and clean out any foreign material to ensure smooth free spool movement.
  • T
    Teresa DiazAug 27, 2025
    How to reduce excessive foaming in my Lancer Dispenser?
    • T
      Timothy EdwardsAug 28, 2025
      To address excessive foaming in your Lancer Dispenser, consider these factors: * Incoming water or syrup temperature may be too high. Correct this prior to the dispenser, and consider a larger dispenser or pre-cooler. * Water flow rate may be too high. Readjust and reset the ratio. * The nozzle and diffuser may not be properly installed. Remove and reinstall them correctly. * The nozzle and diffuser may be dirty. Remove and clean them. * There may be air in the BIB lines. Bleed the air from the BIB lines. * The ice quality may be poor. Check the quality of the ice used in the drink. * The beverage temperature may be high. Check the refrigeration system.
  • A
    Aaron RileyAug 29, 2025
    Why is the ratio erratic in my Lancer Dispenser?
    • T
      Taylor WallerAug 29, 2025
      An erratic ratio in your Lancer Dispenser can be caused by: * Incoming water and/or syrup supply not at minimum flowing pressure. Check the pressure and adjust. * Foreign debris in water and/or syrup flow controls. Remove the syrup flow controls from the upper body and remove any foreign material to ensure smooth free spool movement.
  • E
    Erin GarrettAug 31, 2025
    Why does the compressor on my lancer 1500 POSTMIX Dispenser start and run for a short time but then shut off on overload?
    • H
      harry23Aug 31, 2025
      If the compressor on your Lancer Dispenser starts and runs briefly before shutting off on overload, the following could be the cause: * The condenser may be dirty. Clean the condenser. * There may be insufficient or blocked air flow. Remove all obstructions and allow for minimum clearances of eight (8) inches (20.3 cm) over the top. * The voltage may be inadequate. Measure the voltage across the common and run terminal on the compressor; it must not drop below 90% of the rated voltage. * The wiring may be incorrect. Refer to the wiring diagram and correct it. * The condenser fan motor may be defective. Replace the condenser fan motor. * There could be a refrigerant leak. Repair and recharge the system. * The compressor itself may be malfunctioning. Replace the compressor.
  • A
    ahodgeSep 18, 2025
    Why won't the compressor and condenser fan motor start on my Lancer EIBC (USA Only) dispenser after a 5-minute power off delay?
    • H
      hoffmansteveSep 19, 2025
      If the compressor and condenser fan motor on your Lancer EIBC (USA Only) dispenser won't start after a five-minute power-off delay, consider: * Improper wiring. Check the Power Indicator Lamp and verify the wiring per the Wiring Diagram. * An unplugged probe. Check the probe connection at the PCB. * Damaged electronics. Replace the Control.
  • C
    Carol BennettNov 20, 2025
    What to do if no product is dispensed from my Lancer Dispenser?
    • A
      Alan MontgomeryNov 20, 2025
      If no product is being dispensed from your Lancer Dispenser, there are several potential causes: * The water and syrup shutoffs on the mounting block may not be fully open. Ensure they are fully open. * If it's an electric valve, the key switch might be in the OFF position. Turn it to the ON position. * The cup lever arm or ID panel actuator on an electric valve might not be actuating the switch. This requires repair. * There might be no electric current reaching the valve. Check the current supply; if adequate, inspect the solenoid coil and switch, and replace if necessary. * There could be an improper or inadequate water or syrup supply. Remove the valve from the mounting block, open the shutoffs slightly, and check the supply. If there's no supply, check the dispenser for fre...
  • L
    lewiscolinSep 9, 2025
    What causes a lancer 1500 POSTMIX Dispenser compressor to hum but not start?
    • M
      michael77Sep 9, 2025
      If your Lancer Dispenser's compressor hums but doesn't start, consider these potential causes: * Inadequate voltage. Measure the voltage across the common and run terminal on the compressor. Ensure it doesn't drop below 90% of the rated voltage. * Incorrect wiring. Refer to the wiring diagram and correct it. * A malfunctioning starting relay. Replace the starting relay, making sure to use the correct relay to avoid compressor failure. * A malfunctioning compressor. Replace the compressor.
  • L
    Lisa HarrisSep 6, 2025
    Why does my Lancer Dispenser's compressor start but not switch off the start winding?
    • J
      Jordan JamesSep 6, 2025
      If your Lancer Dispenser's compressor starts but doesn't switch off the start winding (running only briefly before the internal overload switches it off), check for: * Inadequate voltage. Measure the voltage across the common and run terminal on the compressor. * Incorrect wiring. Refer to the wiring diagram and correct it. * A malfunctioning starting relay. Replace the starting relay, ensuring you use the correct relay to prevent compressor failure.

Summary

Installation Procedures

Receiving and Unpacking

Inspect and unpack the dispenser unit upon arrival.

Location and Preparation

Select a suitable counter location and prepare the mounting surface.

Drain and Water Filling

Connect the drain and fill the unit's water bath.

Electrical Power Connection

Safely connect the dispenser to an electrical power source.

Water Supply Setup

Connect to the plain water supply, ensuring NSF compliance.

Carbonated Water and Syrup Lines

Connect carbonated water and syrup supplies and pressurize systems.

Adjusting Dispensing Flow

Adjust water and syrup flow rates for optimal dispensing performance.

Scheduled Maintenance

Daily Maintenance Tasks

Routine daily cleaning of nozzles, diffusers, cup rest, and exterior.

Weekly Maintenance Checks

Weekly checks include product tasting and water bath level inspection.

Monthly Maintenance Procedures

Monthly tasks: unplugging, condenser cleaning, bonnet replacement.

Six-Month and Yearly Service

Six-month cleaning/sanitizing and yearly interior/exterior cleaning.

Dispenser Cleaning and Sanitizing

Ambient Process Cleaning

Method for cleaning and sanitizing using detergent and chlorine solutions.

Valve Cleaning and Sanitizing

Detailed instructions for cleaning and sanitizing dispenser valves.

Troubleshooting Guide

Leakage Diagnosis and Repair

Diagnose and resolve leaks around nozzles, valve bodies, and general unit leakage.

Flow and Ratio Issues

Troubleshoot insufficient water/syrup flow and erratic dispensing ratios.

Dispensing Output Problems

Address no product dispensing and incorrect product/water ratios.

Valve and Foaming Troubleshooting

Resolve issues like valves not shutting off and excessive foaming.

Compressor and Fan Motor Issues

Troubleshoot compressor start failures, run-on, and fan motor operation.

Delayed Start and Warm Drinks

Address delayed compressor/fan start and warm drink dispensing issues.

Illustrations, Parts Lists, and Wiring Diagrams

Wiring Diagram and Control Housing

Electrical wiring diagram and control housing connections for EIBC.

Refrigeration Deck Assembly (USA)

Exploded view and parts list for the USA R-134A refrigeration deck assembly.

Refrigeration Deck Assembly (Export)

Exploded view and parts list for Export R-134A refrigeration deck assemblies.

Cabinet Assembly - High Performance

Exploded view of the Series 1500 cabinet assembly for high performance models.

Cabinet Assembly - E and Premix

Exploded view of the Series 1500E and 1500 Premix cabinet assembly.

lancer SERIES 1500 POSTMIX Specifications