Questions and Answers

  • E
    Elizabeth TerrellSep 23, 2025
    What causes miscellaneous leakage in my lancer Dispenser?
    • D
      Dwayne PerezSep 23, 2025
      If you're experiencing miscellaneous leakage in your lancer Dispenser, consider the following: * Gap between parts: Tighten the appropriate retaining screws. * Damaged or improperly installed o-rings: Replace or adjust the appropriate o-rings.
  • M
    mccoytomAug 25, 2025
    Why is the soda flow insufficient in my lancer IBD 22 Dispenser?
    • K
      Kenneth SmithAug 25, 2025
      If you're experiencing insufficient soda flow in your lancer Dispenser, it could be due to: 1. Insufficient CO supply pressure: Verify the incoming CO pressure is between 70 PSIG (0.483 MPA) and 80 PSIG (0.552 MPA). 2. The shutoff on the mounting block is not fully open: Ensure the shutoff is fully open. 3. Foreign debris in the soda flow control: Remove the soda flow control from the valve and clean out any foreign material to ensure smooth spool movement.
  • B
    Brian CampbellAug 25, 2025
    How to fix insufficient water flow in lancer IBD 22 Dispenser?
    • L
      Lauren CookAug 26, 2025
      If you're getting insufficient water flow from your lancer Dispenser, consider the following: * Insufficient incoming supply pressure: Verify the incoming supply water pressure to the plain water inlet is a minimum of 50 PSI (0.345 MPA) and a maximum of 100 PSI (0.689 MPA). * Shutoff on mounting block not fully open: Open the shutoff fully. * Foreign debris in water flow control: Remove the water flow control from the valve and clean out any foreign material to ensure smooth spool movement. * Water filtration problem: Service the water system as required.
  • E
    Elizabeth MeyerAug 27, 2025
    Why is my lancer IBD 22 Dispenser producing low or no carbonation?
    • M
      Michael CookAug 27, 2025
      If your lancer Dispenser has low or no carbonation, check the following: * Low or no CO: Check the CO supply. * Low water pressure: A water booster kit might be needed. * Worn or defective carbonator pump: Consider replacing the carbonator pump. * Backflow preventer not allowing water to flow: Replace the backflow preventer, noting the flow direction arrow from pump to coldplate. * Probe malfunctioning: Replace the probe. * PCB malfunctioning: Replace the PCB.
  • N
    Nicole MorrisAug 27, 2025
    How to stop excessive foaming in lancer Dispenser drinks?
    • J
      Jessica WilsonAug 27, 2025
      To address excessive foaming in drinks from your lancer Dispenser, consider these points: * No ice in bin: Fill the bin with ice and allow the coldplate to re-stabilize. * Incoming water or syrup temperature too high: Correct this prior to the dispenser. * CO pressure too high: Adjust the CO pressure downward, but not less than 70 PSI (0.483 MPA). * Water flow rate too high: Re-adjust and reset the ratio. * Nozzle and diffuser not clean: Remove and clean them. * Air in BIB lines: Bleed air from the BIB lines.
  • S
    Stephen ScottSep 13, 2025
    What causes water leakage around the nozzle of my lancer Dispenser?
    • M
      Monica DaughertySep 14, 2025
      If you're experiencing water leakage around the nozzle of your lancer Dispenser, it could be due to: * Damaged or improperly installed o-ring on nozzle: If damaged, replace. If improperly installed, adjust.
  • T
    tracy58Sep 12, 2025
    What to do if the valve will not shut off on my lancer Dispenser?
    • H
      Haley GonzalesSep 12, 2025
      If the valve on your lancer Dispenser won't shut off, try the following: * Debris in paddle arms: Activate the valve a few times to free debris. Clean out any foreign material. * Solenoid plunger sticking: Replace the solenoid coil.
  • M
    michael60Sep 12, 2025
    Why does the BIB pump continue to run when the syrup bag is empty on my lancer IBD 22 Dispenser?
    • J
      jacobhermanSep 13, 2025
      If the BIB pump continues to run after the bag is empty in your lancer Dispenser, it could be due to: * Leak in suction line: Check the BIB connector, if still leaking then replace the line. * Leaking o-ring on pump inlet fitting: Replace the o-ring. * Defective syrup BIB pump: Replace the defective pump.
  • A
    Amy StewartSep 4, 2025
    Why does my lancer Dispenser have an erratic ratio?
    • B
      brownhelenSep 4, 2025
      An erratic ratio in your lancer Dispenser could be due to: * Incoming water and/or syrup supply not at minimum flowing pressure: Check pressure and adjust. * Foreign debris in water and/or syrup flow control: Remove flow control from suspected valve and clean out any foreign material to ensure smooth spool movement. * CO regulator malfunction: Repair or replace CO regulator.
  • J
    jennifer94Sep 2, 2025
    Why is my lancer Dispenser dispensing syrup and CO gas, but no water?
    • D
      denise91Sep 2, 2025
      If your lancer Dispenser is dispensing syrup and CO gas, but no water, consider the following possible causes: * Improper water flow to dispenser: Check for water flow to dispenser. * Carbonator pump motor has timed out: Reset by turning the unit OFF, then ON by using the circuit breaker on the power supply or momentarily unplugging unit. * Liquid level probe not connected properly to PCB: Check connections of liquid level probe to PCB assembly. * Defective PCB assembly: Replace PCB assembly. * Defective liquid level probe: Replace liquid level probe. * Weak or defective carbonator pump: Replace pump.