Questions and Answers

  • E
    Elizabeth WilsonSep 10, 2025
    Why is the BIB pump operating, but there is no syrup flow in my lancer Dispenser?
    • D
      Danielle GonzalezSep 12, 2025
      If the BIB pump is running, but there's no syrup flow in your lancer Dispenser, it could be due to: * Leak in syrup inlet or outlet line: Replace the line. * Defective BIB pump: Replace the BIB pump.
  • J
    Jonathan FaulknerSep 9, 2025
    Why is my lancer Dispenser not dispensing ice, or dispensing poor quality ice?
    • R
      Rebecca Warren DDSSep 9, 2025
      If the ice door opens, the motor runs, but no ice dispenses (or the ice is of poor quality) from your lancer Dispenser, consider these possibilities: * Dispenser is out of ice: Fill the dispenser with ice. * Agitator pin is missing or damaged: Replace the agitator pin. * Poor ice quality: Service the ice machine. * Key not installed on agitation shaft: Install the key on the agitation shaft.
  • J
    Jennifer HernandezSep 8, 2025
    Why does the motor run but the ice door doesn't open on my lancer IBD 22?
    • B
      Brian BrownSep 8, 2025
      If the motor runs but the ice door doesn't open when using the push chute on your lancer Dispenser, check these potential issues: * Solenoid not connected to PC board: Connect the solenoid to the PC board. * Solenoid defective: Replace the solenoid. * PC board defective: Replace the PC board.
  • T
    Travis MiddletonAug 22, 2025
    What to do if the lancer IBD 22 has no power when activated?
    • A
      Arthur PriceAug 23, 2025
      If your lancer Dispenser doesn't power on when activated (and the switch panel isn't lit), there are several possible causes: * A malfunctioning switch assembly: Consider replacing the switch assembly. * No power to the dispenser: Check the internal breaker and incoming power. * A malfunctioning power supply: Check the voltage to the power supply and inspect the fuses. * A malfunctioning PCB board: Replacement of the PCB board may be necessary.
  • G
    George KingSep 5, 2025
    What to do if the ice door opens but the motor doesn't run on my lancer Dispenser?
    • J
      justin98Sep 5, 2025
      If the ice door opens when you use the push chute on your lancer Dispenser, but the motor doesn't run, consider these potential problems: * Wiring harness not plugged in: Plug in the wiring harness. * PC board defective: Replace the PC board. * Motor defective: Replace the motor.
  • A
    Amy StewartSep 4, 2025
    Why does my lancer Dispenser have an erratic ratio?
    • B
      brownhelenSep 4, 2025
      An erratic ratio in your lancer Dispenser could be due to: * Incoming water and/or syrup supply not at minimum flowing pressure: Check pressure and adjust. * Foreign debris in water and/or syrup flow control: Remove flow control from suspected valve and clean out any foreign material to ensure smooth spool movement. * CO regulator malfunction: Repair or replace CO regulator.
  • M
    Mark WardSep 3, 2025
    What to do if the lancer IBD 22 push chute has no response?
    • B
      Brian MathisSep 3, 2025
      If the push chute on your lancer Dispenser isn't responding, check these potential causes: * Dispenser not connected to power source: Connect the dispenser to a power source. * Wiring harness not plugged in: Plug in the wiring harness. * PC board defective: Replace the PC board. * Malfunctioning power supply: Check the voltage to the power supply and check the fuses.
  • J
    jennifer94Sep 2, 2025
    Why is my lancer Dispenser dispensing syrup and CO gas, but no water?
    • D
      denise91Sep 2, 2025
      If your lancer Dispenser is dispensing syrup and CO gas, but no water, consider the following possible causes: * Improper water flow to dispenser: Check for water flow to dispenser. * Carbonator pump motor has timed out: Reset by turning the unit OFF, then ON by using the circuit breaker on the power supply or momentarily unplugging unit. * Liquid level probe not connected properly to PCB: Check connections of liquid level probe to PCB assembly. * Defective PCB assembly: Replace PCB assembly. * Defective liquid level probe: Replace liquid level probe. * Weak or defective carbonator pump: Replace pump.
  • A
    Anthony JohnsonSep 1, 2025
    What causes the circuit breaker to trip on my lancer IBD 22 Dispenser?
    • E
      Evelyn HenrySep 1, 2025
      If the circuit breaker is tripping on your lancer Dispenser, try these troubleshooting steps: * Valve wire harness shorted to itself or faucet plate: Detect short by disconnecting valve harnesses from switch panel (4 25-pin harnesses and 4 9-pin harnesses). Restore power. If breaker does not trip, find and replace shorted harness. * Controller PCB is bad: Detect by disconnecting the white 5-pin harness from the controller PCB. Restore power. If breaker does not trip, replace controller PCB. * Secondary wire harness has a short: Locate short from a motor or solenoid harness and replace. * Power supply is bad: Detect short by disconnecting all harnesses connected to power supply. Restore power. If breaker still trips, replace power supply.
  • S
    Sharon RichardsonAug 31, 2025
    Why is my lancer IBD 22 dispensing only water or only syrup?
    • S
      Sherry SimonAug 31, 2025
      If your lancer Dispenser is dispensing only water or only syrup, here are some potential causes: * Syrup BIB empty: Replace the syrup BIB as required. * Water or syrup shutoff on mounting block not fully open: Open shutoff completely. * Improper or inadequate water or syrup supply: Remove valve from mounting block & open shutoffs slightly. Check water & syrup supply. If no supply, check unit for other problems. Ensure BIB connection is engaged. * CO pressure to syrup pump too low: Check the CO pressure to the pump to ensure it is between 70-80 PSI (0.483-0.552 MPA). * Stalled or inoperative BIB pump: Check CO pressure and/or replace pump. * Kinked line: Remove kink or replace line. * CO regulator malfunction: Repair or replace CO regulator as required.