Why is there insufficient syrup flow in my lancer IBD 22?
- AAlicia BallardAug 30, 2025
If you're experiencing insufficient syrup flow in your lancer Dispenser, consider the following: * Insufficient CO pressure to BIB pumps: Adjust CO pressure to BIB pumps to 80 PSI (0.552 MPA) (min. 70 PSI (0.483 MPA). Do not exceed manufacturer’s recommendations. * Shutoff on mounting block not fully open: Open the shutoff fully. * Foreign debris in syrup flow control: Remove the syrup flow control from the valve and clean out any foreign material to ensure smooth spool movement. * Defective BIB pump: Replace the pump.