IBD 22
IBD 30
Lancer Corporation
6655 Lancer Blvd.
San Antonio, Texas 78219
800-729-1500
Technical Support/Warranty: 800-729-1550
email: custserv@lancercorp.com
web: lancercorp.com
Lancer PN: 28-0255/14
Revision: September 2018
Operation Manual
“Lancer” is the registered trademark of Lancer © 2018 by Lancer, all rights reserved.
®
4500

Table of Contents

Other manuals for lancer IBD 22

Questions and Answers

  • A
    Aaron BentleyAug 29, 2025
    Why is there insufficient syrup flow in my lancer IBD 22?
    • A
      Alicia BallardAug 30, 2025
      If you're experiencing insufficient syrup flow in your lancer Dispenser, consider the following: * Insufficient CO pressure to BIB pumps: Adjust CO pressure to BIB pumps to 80 PSI (0.552 MPA) (min. 70 PSI (0.483 MPA). Do not exceed manufacturer’s recommendations. * Shutoff on mounting block not fully open: Open the shutoff fully. * Foreign debris in syrup flow control: Remove the syrup flow control from the valve and clean out any foreign material to ensure smooth spool movement. * Defective BIB pump: Replace the pump.
  • M
    Mr. Walter Swanson MDAug 28, 2025
    What to do if lancer IBD 22 Dispenser has no product but the switch panel is lit?
    • S
      sarahscottAug 28, 2025
      If your lancer Dispenser's switch panel is lit but no product is dispensed, the issue might stem from: * Keyswitch is off or keyswitch harness is disconnected: Turn the keyswitch on and/or reconnect the keyswitch harness. * Malfunctioning switch assembly: Consider replacing the switch assembly. * Malfunctioning VersaPour valve: Replace the module.
  • N
    Nicole MorrisAug 27, 2025
    How to stop excessive foaming in lancer Dispenser drinks?
    • J
      Jessica WilsonAug 27, 2025
      To address excessive foaming in drinks from your lancer Dispenser, consider these points: * No ice in bin: Fill the bin with ice and allow the coldplate to re-stabilize. * Incoming water or syrup temperature too high: Correct this prior to the dispenser. * CO pressure too high: Adjust the CO pressure downward, but not less than 70 PSI (0.483 MPA). * Water flow rate too high: Re-adjust and reset the ratio. * Nozzle and diffuser not clean: Remove and clean them. * Air in BIB lines: Bleed air from the BIB lines.
  • E
    Elizabeth MeyerAug 27, 2025
    Why is my lancer IBD 22 Dispenser producing low or no carbonation?
    • M
      Michael CookAug 27, 2025
      If your lancer Dispenser has low or no carbonation, check the following: * Low or no CO: Check the CO supply. * Low water pressure: A water booster kit might be needed. * Worn or defective carbonator pump: Consider replacing the carbonator pump. * Backflow preventer not allowing water to flow: Replace the backflow preventer, noting the flow direction arrow from pump to coldplate. * Probe malfunctioning: Replace the probe. * PCB malfunctioning: Replace the PCB.
  • B
    Brian CampbellAug 25, 2025
    How to fix insufficient water flow in lancer IBD 22 Dispenser?
    • L
      Lauren CookAug 26, 2025
      If you're getting insufficient water flow from your lancer Dispenser, consider the following: * Insufficient incoming supply pressure: Verify the incoming supply water pressure to the plain water inlet is a minimum of 50 PSI (0.345 MPA) and a maximum of 100 PSI (0.689 MPA). * Shutoff on mounting block not fully open: Open the shutoff fully. * Foreign debris in water flow control: Remove the water flow control from the valve and clean out any foreign material to ensure smooth spool movement. * Water filtration problem: Service the water system as required.
  • M
    mccoytomAug 25, 2025
    Why is the soda flow insufficient in my lancer IBD 22 Dispenser?
    • K
      Kenneth SmithAug 25, 2025
      If you're experiencing insufficient soda flow in your lancer Dispenser, it could be due to: 1. Insufficient CO supply pressure: Verify the incoming CO pressure is between 70 PSIG (0.483 MPA) and 80 PSIG (0.552 MPA). 2. The shutoff on the mounting block is not fully open: Ensure the shutoff is fully open. 3. Foreign debris in the soda flow control: Remove the soda flow control from the valve and clean out any foreign material to ensure smooth spool movement.