INSTALLATION AND SERVICE MANUAL
FOR
LANCER LEV
® FILL STATION (LFS)
(PN 85-0087)
REV: 10/15/01
P.N. 28–0507
THIS MANUAL IS AN INITIAL ISSUE.
6655 LANCER BLVD. • SAN ANTONIO, TEXAS 78219 USA • (210) 310-7000
FAX SALES
USA -CANADA – 210-310-7250 • LATIN AMERICA – 210-310-7245 • ASIA – 210-310-7242
EUROPE – 32-2-755-2399 • PACIFIC – 61-8-8268-1978
FAX ENGINEERING: 210-310-7096
"Lancer" is the registered trademark of Lancer Copyright — 2001 by Lancer, all rights reserved.
NOTICE TO USERS:
THIS DISPENSER UNIT IS INTENDED FOR IN-DOOR USE ONLY.
Please refer to the Lancer web site (www.lancercorp.com) for
information relating to Lancer Installation and Service Manuals,
Instruction Sheets, Technical Bulletins, Service Bulletins, etc.

Questions and Answers

  • M
    Michael PerezAug 20, 2025
    Why is there no product dispensed from my Lancer Dispenser?
    • S
      Sean Smith MDAug 20, 2025
      If no product is dispensed from your Lancer Dispenser, several factors could be at play. First, ensure that the water and syrup shutoffs are fully OPEN. Next, check that the cup lever arm or I.D. Panel actuator is actuating the switch; if not, repair or replace it. Verify that electric current is reaching the valve according to the specifications, and if adequate, inspect the solenoid coil and switch, replacing them if necessary. Also, check for proper water and syrup supply by removing the valve from the mounting block and slightly opening the stems. If there's no supply, inspect the dispenser for freeze-up or other issues. Finally, ensure that the BIB (Bag-In-Box) is not empty and replace it if needed.
  • Y
    yrichardsonAug 22, 2025
    What to do if my Lancer Dispenser valve will not shut OFF?
    • A
      Angela AllenAug 22, 2025
      If the valve on your Lancer Dispenser won't shut OFF, there are several possible causes. The cup lever might be sticking or binding, so try to correct or replace the lever. The switch might not be actuating properly, so check it for free actuation. The solenoid armature might not be returning to its bottom position, in which case you should replace the defective solenoid armature or spring. Finally, there could be debris or damage to the paddle arms; remove any debris and/or replace the damaged paddle arms.
  • J
    Jennifer DixonAug 25, 2025
    What to do if my Lancer Dispenser is dispensing water only or syrup only?
    • C
      Christopher GloverAug 25, 2025
      If your Lancer Dispenser is dispensing only water or only syrup, start by checking that the water or syrup stem on the mounting block is fully OPEN. If the stems are open, remove the valve from the mounting block and open the stem slightly to check for proper syrup and water supply. If there is no supply, check the dispenser for freeze-up or other problems.
  • R
    Roberta HernandezAug 26, 2025
    How to fix excessive foaming in my Lancer Dispenser?
    • M
      Melissa HillAug 26, 2025
      To address excessive foaming in your Lancer Dispenser, consider the following: * Ensure that the incoming water or syrup temperature is not too high. * Readjust and reset the oBrix if the water flow rate is too high. * Clean the nozzle and diffuser if they are not clean. * Properly install the nozzle and diffuser if they are not correctly installed. * Check the CO2 pressure to ensure it is set correctly.
  • J
    Joseph KlineAug 28, 2025
    What to do if the SOLD OUT alarm on my Lancer Dispenser does not shut OFF?
    • P
      Peter RiosAug 28, 2025
      If the SOLD OUT alarm on your Lancer Dispenser does not shut OFF, it could be due to a few reasons. First, check if the pressure switch is ON. If it is, check the syrup supply, syrup bag line connections, and CO2 supply. Also, check for loose connections. If none of these resolve the issue, you may need to replace the pressure switch. If the problem persists, the PCB may have failed, requiring replacement.
  • C
    Colton GonzalezAug 29, 2025
    Why won't my Lancer Dispenser go into AUTO mode?
    • M
      Melissa WhiteAug 30, 2025
      If your Lancer Dispenser won't go into AUTO mode, first check to ensure the cables are plugged in correctly. If the issue persists, the switch might be broken and need replacement. If neither of these solutions works, the PCB may have failed and require replacement.
  • H
    Hunter CalderonAug 31, 2025
    Why is water not dispensing from the valve of my Lancer Dispenser?
    • R
      Ryan ConradAug 31, 2025
      If water is not dispensing from the valve of your Lancer Dispenser, first check that the water supply is on. If the water is on, ensure there are no leaks or clogs in the chiller and that the chiller is ON.
  • J
    Julie Cox MDSep 2, 2025
    How to fix insufficient water flow in my Lancer Dispenser?
    • D
      Diana BennettSep 2, 2025
      To fix insufficient water flow in your Lancer Dispenser, first check the incoming water from the carbonator to ensure minimum flowing pressure. Also, remove the water flow control from the upper body and clean out any foreign materials to ensure smooth free piston movement.
  • D
    Dawn GrahamSep 4, 2025
    How to fix insufficient syrup flow in my Lancer Dispenser?
    • J
      joshua16Sep 5, 2025
      To fix insufficient syrup flow in your Lancer Dispenser, first check the incoming syrup to ensure minimum flowing pressure. Also, remove the syrup flow control from the upper body and clean out any foreign materials to ensure smooth free piston movement.
  • K
    Kimberly HamptonSep 6, 2025
    What does it mean if my Lancer Dispenser has an erratic Ratio oBrix?
    • D
      Donald LeonardSep 6, 2025
      An erratic Ratio oBrix in your Lancer Dispenser can be caused by insufficient flowing pressure in the incoming water and/or syrup supply. Check both to ensure they have sufficient flowing pressure. It can also be caused by foreign debris in the water and/or syrup flow controls. Remove the flow controls and clean out any foreign materials to ensure smooth free piston movement.

Summary

Introduction to Lancer LEV Fill Station

Lancer LEV Fill Station Specifications

Lancer LEV Fill Station Specifications Details

Details of shipping weight, dimensions, electrical, and connection types.

Lancer LEV Fill Station Installation

Receiving and Unpacking the LFS

Instructions for inspecting the unit upon arrival and removing it from packaging.

LFS Mounting and Installation

Guidelines for physically mounting the dispenser, including clearance and drilling.

Electrical and Supply Line Connections

Procedures for connecting the unit to power and water/syrup sources.

Lancer LEV Fill Station Scheduled Maintenance

Daily Cleaning of LFS

Daily tasks for cleaning the nozzle, diffuser, and unit exterior.

Bi-Weekly LFS Sanitization

Procedure for sanitizing the nozzle and diffuser every two weeks.

Six-Month LFS Maintenance

Guidance for comprehensive cleaning and sanitizing every six months.

Lancer LEV Fill Station Cleaning and Sanitizing

Ambient Process for LFS Cleaning and Sanitizing

Detailed steps for the ambient cleaning and sanitizing process.

Lancer LEV Fill Station Operation

LFS Connections and Initial Power Up

Steps for connecting supply lines and powering on the unit for the first time.

LFS Dispensing Modes (Auto and Manual)

Explanation of how to operate the unit in Auto and Manual dispensing modes.

Setting the Desired Ratio on LFS

Procedures for adjusting water flow and water-to-syrup brix ratio.

Syrup Package Management and LFS Alarms

How to change syrup packages and understand unit alarms.

Lancer LEV Fill Station Troubleshooting

Troubleshooting LFS Power and Mode Issues

Solutions for power light not coming on or unit not entering auto mode.

Troubleshooting LFS Dispensing and Alarm Problems

Diagnosing issues like alarms not shutting off or no product dispensing.

Troubleshooting LFS Leakage and Flow Issues

Addressing water leakage and insufficient water or syrup flow.

Troubleshooting LFS Ratio and Foaming Issues

Resolving erratic ratios, no product dispensed, or excessive foaming.