EasyManua.ls Logo

Laspaziale Mini Vivaldi - Connection Diagrams; Electrical Connection Diagram; Control Board Connection Diagram; Triac Board Connection Diagram

Laspaziale Mini Vivaldi
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 20
5.5 Damaged Group Heating Element Triac / SSR
This alarm is a blocking one, and occurs when the group triac always remains in
conduction (temperature >140°C). The lights 20-21 are flashing.
Turn off the Mini V2 and request service. Note: new machines use a dual Solid State
Relay (SSR) rather than the triac.
5.6 Damaged Boiler Heating Element Triac SSR
(only with the boiler turned on)
This alarm is a blocking one, and occurs when the boiler triac always remains in
conduction (temperature >140°C). The lights 19-20-21 are flashing.
Turn off the Mini V2 and request service. Note: new machines use a dual Solid State
Relay (SSR) rather than the triac.
5.7 Boiler Automatic Refill System Failure
(only with the boiler turned on)
This is a blocking alarm which is signaled by blinking of the Boiler (13) light. If the pump
runs for more than 1 minute attempted to refill the boiler without the controller circuit
receiving a boiler full signal, this alarm is triggered.
This alarm can be temporarily cancelled by pressing the BOILER (26) button to turn off
the boiler. The Mini VII can be operated with the steam boiler off until repairs to the
boiler function occur.

Related product manuals