Page 16
To enter a negative temperature offset between 0˚C and -8˚C mode push the Double
Cup button. Each press will change the offset by -1˚C. An offset of 0˚C is designated
by all temperature lamps off. A -8˚C offset is designated by all temperature lamps plus
EMPTY on. If your negative offset is more than you wish, each press of the Single Cup
button changes the offset by +1˚C.
How Do I Tell If My Current Offset is Negative or Positive?
Example: You enter Offset Programming mode and see that three lamps are on. This
can indicate either ±3˚C. Which is it? Since each press of the Double Cup button
changes the offset by -1˚C, press it and see what happens. There will either be two or
four lamps lit. If four lamps are lit the offset must have been -3˚C since pressing
Double Cup always changes the setting by -1˚C with each press. If two lamps are lit
the offset was +3˚C. By pressing Double Cup the offset has changed to +2˚C.
-8 -7 -6 -5 -4 -3 -2 -1 0 +1 +2 +3 +4 +5 +6 +7 +8 ˚C Offset
----------------------------------------------------------! Single Cup Button
"--------------------------------------------------------- Double Cup Button
Note that neither the Single Cup nor the Double Cup button presses wrap around
when they reach the limit of their range. Once you get to +8˚C additional presses of the
Single Cup button do nothing. Same with the Double Cup button once -8˚C is reached.
See table below:
Offset
91ºC
Lamp
92ºC
Lamp
93ºC
Lamp
94ºC
Lamp
95ºC
Lamp
96ºC
Lamp
97ºC
Lamp
EMPTY
Lamp
0ºC
Off
Off
Off
Off
Off
Off
Off
Off
±1ºC
On
Off
Off
Off
Off
Off
Off
Off
±2ºC
On
On
Off
Off
Off
Off
Off
Off
±3ºC
On
On
On
Off
Off
Off
Off
Off
±4ºC
On
On
On
On
Off
Off
Off
Off
±5ºC
On
On
On
On
On
Off
Off
Off
±6ºC
On
On
On
On
On
On
Off
Off
±7ºC
On
On
On
On
On
On
On
Off
±8ºC
On
On
On
On
On
On
On
On
4.11.3 Steam Pressure Adjustment
Steam pressure can be adjusted up or down in 1, 2, or 3 increments of slightly less than
0.1 bar each. The overall pressure range is from approximately 0.9 bar to about 1.4

Related product manuals