8
S
tandardGridConnectSystem
W
ARNING:
TheInverteroutputisconnectedtomainselectricity
,thusitisimport
antthatall
ACwiringcomplies
withtherequirement
softherelevantwiringst
andards,(AS3000,
AS4777).
Anyworkcarriedouton
AC/MainswiringistobeperformedbyQualified
AndLicensed
personnelonly
.
SolarPanels
GridMains
Switchboard
Power
Power
Lights
Lights
Hot
W
ater
S
tove
AirCon
(Exampleonly)
10A
Legend
=CircuitBreaker
ExportMeter
Import
Meter
DIP SWITCHSETTINGS
Switch1-MPPT/Batterymode
Switch2-50/60Hz
Switch4
Switch5
Switch6
IntheONposition theMaximumPowerPoint Trackingisenabled.
ThisisrequiredwhentheDCinputisPhotovoltaicSolarModulesonly.
IntheOFFpositiontheMaximumPowerPoint Trackingisdisabledandthe
voltagetrackingwilloperateatafixedvoltageof54V(PVE1200)or108V
(PVE2500). Thissettingisrequiredinasystemwherea48V(PVE1200)or
96V(PVE2500)BatteryBankisrequiredontheDCinput.
IntheONpositiontheInverterissetfor60Hzoperation.
IntheOFFposition theInverterissetfor50Hzoperation.
MustbeinOFFposition fornormaloperation. TheONpositionisa
factory ACtestsetting.
MustbeintheOFFposition fornormaloperation. TheONposition
isafactoryDCtestsetting.
Notused.
(default)
(default)
(IfSwitch1OFF) (IfSwitch1ON)
(Default)
(default)
(default)
Switch3
ON=Gel/SLA battery. ON=255VACsustainedoperation
OFF=Floodedbattery. OFF=Sustainedoperationturnedoff
13
DIP SWITCHLOCATION
MAINPCB
DIP SwitchlocatedonMainPCB
123456
OFF
ON
WARNING:
Duetodangerousvoltagesexistinginsidetheunit,makesure
theexternalDCand ACsolarisolatorsareturnedoffbefore
openingtheunit.Only arepermittedto
adjustthesesettings.
qualifiedTradesPersons
PV
Edge