DCSolarConnector
Foreasyconnectionand
disconnectionofDCInput
PowerfromSolarPanels
orBatteryBank.
Fan
Ifthetemperatureinsidethe
Inverterreachespresetlevels,the
variablespeedfanwillswitchon
initiallyinlowspeedandtheninto
higherspeedifthetemperature
continuestoincrease.Obstruction
oftheairintakeandoutputwill
reducethepowerratingofthe
Inverter.
DigitalEnergyMeter
Usingtheyellowbuttonyouare
abletoscrollthroughthe
differentvalues.Seepage14
formoredetails.
Plug&Play AC
Connector
Foreasyconnectionand
disconnectionto ACgrid.
INVERTEROPERATION
WhentheInverterisswitchedonall4LED'Slightupfor1secondwhilethe
microprocessorperformsastartupandsystemcheckprocedure.
100%LED(Overload)
ThisLEDindicatesovertemp/overload.
InthismodetheallotherLED’swillbe
OFFandthisLEDwillflash.
75%LED(ACGrid)
ThisLEDhas2modesofoperation.
ThisLEDwillbeONsolidwithallotherLED’soff
whenthesolarinputispresentandthe ACgrid
isdisconnectedand/orawaitingreconnection.
ThisLEDwillFLASHfor90secondswithall
otherLED’soffwhentheinverterinitially
connectstothe ACgridandperformsavoltage
andfrequencystabilitycheckbeforefeeding
powerintothe ACgrid.
50%LED(ACFault)
Whenan ACfaultispresentthisLEDwill
FLASHandallotherLED’soff
25%LED
ThisLEDwillflashwithallotherLED’soff
duringabatterymaintenancecycle(see
pg12).
IndicatorLamps
The4LED’sonthefrontpanelaredualpurpose.
Wheninnormalrunmodetheyoperate
asabargraph
LED4-76%-100%(topLed).
LED3-51%-75%.
LED2-26%-50%.
LED1-1%-25%.(BottomLed).
IftheInverterweresupplying60%of
FullpowerthenLed’s1,2&3wouldbeilluminated.