EasyManua.ls Logo

Latronics PVE1200 - Wiring Diagrams

Latronics PVE1200
12 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7
BatteryBack-UpSystem
10A
Legend
PV
Edge
LSInverter
SolarPanels
AC
T
ransferSwitch
(ACTS
-
2)
Regulator
(Optional)
Switchboard
Power
Power
Lights
Lights
Hot
W
ater
S
tove
AirCon
(Exampleonly)
PVE1200
48V
(min200Ahrs)
PVE2500
96V
(min200Ahrs)
Batteries
=CircuitBreaker
AC
DC
10A
ExportMeter
Import
Meter
GridMains
14
!
!
!
TheDCinputissuitableforconnectiontosolarmodulesonly,when
MPPT isenabled.
DonotexceedrecommendedMaximumDCInputPower.
! Allsolarmodulesshouldbeofthesametypeandbrand. Therefore
themaximumpowerpointandvoltagevariationwithtemperatureare
consistentforallmodules,whichwillensuremaximumsystemoutput.
SOLARINPUTCONFIGURATION
EnergyMeter
! ThePVEdgemetershowsthefollowingmeasurementsonscreen.
ToscrollthroughthevaluesUsethebuttonbelowthescreen.
Instantaneouspowerthatisbeinggenerated.
ResettableaccumulativePower(kWhmeter)
OutputVoltage(V)
OutputCurrent(A)
OutputFrequency(Hz)
OutputPowerFactor
Note:
kW:
kWh:
V:
A:
F:
PF:
ToresettheResettablekWhmeter.Pressonholdfor10sec
235 8.
A kWhV
00125 6.
ValuesofInvertersoutput
Non-resettable kWh meter
http://www.latronics.com.au/products/grid-connect-inverter-pv-edge-series
ToconfigureyourpanelswiththePVEdgeinverter pleasegoto