EasyManua.ls Logo

Lauda MC 600 - Hydraulic Circuit; Voltage-Dependent Data

Default Icon
72 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
11.3
Hydraulic circuit
Fill capacity Maximum
flow
Maximum
flow pres-
sure
Pump con-
nection
Drain tap Overflow con-
nection
Litres
l/min (water
20 °C)
bar (water
20 °C)
(internal
diameter
in mm)
(internal diam-
eter in mm)
MC 250 2 ... 4 16 0.35
Olive ½" (10) G ½" Olive ½" (10)
MC 600 4 ... 8 35 1.3
G ¾ (15),
olive ¾"
G ½"
Olive 16 mm
(12)
MC 1200 7 ... 14 35 1.3
G ¾ (15),
olive ¾"
G ½"
Olive 16 mm
(12)
MC 1200 W 7 ... 14 35 1.3
G ¾ (15),
olive ¾"
G ½"
Olive 16 mm
(12)
11.4
Voltage-dependent data
Power consumption
MC 250 MC 600 MC 1200 MC 1200 W
kW kW kW kW
230 V; 50 Hz 0.23 0.7 1.15 1.2
Catalogue numbers
MC 250 MC 600 MC 1200 MC 1200 W
230 V; 50 Hz LWM 118 LWM 120 LWM 121 LWM 122
220 V; 60 Hz LWM 218 LWM 220 LWM 221 LWM 222
115 V; 60 Hz LWM 418 LWM 420 LWM 421 LWM 422
100 V; 50/60 Hz LWM 618 LWM 620 LWM 621 LWM 622
Technical data
Microcool 62