Command Type Description
PA R Actual Pt value in current units
RA R Actual Rate value in current units
SA R Actual Ps1 value in current units
DA R Actual Ps2 value in current units
PT R Read current Pt target value
PT=n W Set Pt target value to n
RT R Read current Rate target value
RT=n W Set Rate target value to n
ST R Read current Ps1 target value
ST=n W Set Ps1 target value to n
DT R Read current Ps2 target value
DT=n W Set Ps2 target value to n
PJ=n W Jog up (n=0) or down (n=1) Pt target
RJ=n W Jog up (n=0) or down (n=1) Rate target
SJ=n W Jog up (n=0) or down (n=1) Ps1 target
DJ=n W Jog up (n=0) or down (n=1) Ps2 target
PU R Read current Pt units (value returned: 1 to 9)
PU=n W Set Pt units as per following:
n units
1 knots
2 mach
3 Pt inHg
4 Qc inHg
5 Pt mb
6 Qc mb
7 mph
8 kmph
9 EPR
SU R Read current Ps1 units (value returned: 1 to 4)
SU=n W Set Ps1 units as follows:
n units
1 Feet
2 inHg
3 meters
4 mbar
DU R Read current Ps2 units (value returned: 1 to 8)