Command Type Description
DU=n W Set Ps2 units as follows:
n units
1 Diff. inHg
2 inHg
3 Diff. mbar
4 mbar
5 Feet
6 meters
7 knots
8 kmph
PM R Read current Pt mode
PM=n W Set Pt mode to Measure (1), Leak (2), Control (3)
SM R Read current Ps1 mode
SM=n W Set Ps1 mode to Measure (1), Leak (2), Control (3)
DM R Read current Ps2 mode
DM=n W Set Ps2 mode to Measure (1), Leak (2), Control (3)
ER R Read current error ; 0 if no error
L1 R Read max. knots limit
L1=n W Set max. knots limit
L2 R Read max. differential limit in inHg
L2=n W Set max. differential limit in inHg
L3 R Read max. Mach limit
L3=n W Set max Mach limit
L4 R Read max. altitude limit
L4=n W Set max. altitude limit
L5 R Read min. altitude limit
L5=n W Set min. altitude limit
L6 R Read max. altitude rate limit
L6=n W Set max. altitude rate limit
KR R Read current Knots rate
KR=n W Set Knots rate to n
PF R Read current profile point
PF=n W Set current profile point to n (xx.xx)