68
Command Type Description
GO W Command to execute current settings.
CN W Command to cancel current settings
IE R Read current IEEE address
IE=n W Set IEEE address to n
HC R Read current Height Correction
HC=n W Set Height Correction to n
C1 R Read Pt vacuum calibration point
C1=n W Set Pt vacuum calibration point
C2 R Read Pt full-scale calibration point
C2=n W Set Pt full-scale calibration point
C3 R Read Ps1 and Ps2 vacuum calibration point
C3=n W Set Ps1 and Ps2 vacuum calibration point
C4 R Read Ps1 and Ps2 full-scale calibration point
C4=n W Set Ps1 and Ps2 full-scale calibration point
CC W Activate new calibration points after new values have
been entered.
SF=0 R Read the status of the Self Test last performed.
SF=1 W Start the Self Test.
SG W Set 'Ground'
GG W Go To 'Ground'
F3 W Change the main screen to 3-output format
F2 W Change the main screen to 2-output format

Related product manuals