- 15 -
ITALIANOENGLISH
ELECTRIC CONNECTIONS
Attention
- The manufacturer strongly recommends the use of his control units.
- All connection operations must be performed without electric mains.
Power supply cable
Fig. 13
Fig. 12
BOOST 5 - 230Vac
BOOST 10 - 230Vac
Cable4x0,5mm
Colour
BOOST 24 - 24Vdc
Cable2x1,5mm Colour
Common Blue Positive engine input
Green or
Red
Engine OPEN Black Negative engine input
Brown or
Black
Engine CLOSE Brown
Ground Yellow-Green
Unlocking the gearmotor
The unlocking is made by a key that is to be kept by user in a sure
and easily reachable place. In order to obtain the unlocking of the
operator, proceed as follows:
f
- Put the key into the lock and rotate it clockwise for 90° (fig. 12).
- Pull outwards the lever up to the stop (fig. 13). Now it is possible to move
the gate manually.
- To lock the operator, push the lever back and rotate for 90° counter
clockwise the key.
Attention: during unlocking, don't put too much force on the
key, to avoid risk of breaking it.