45
PARAMETER MENU
PARAM. PARAMETER RANGE OF FACTORY
NUMBER NAME ADJUSTMENT DEFAULT
32 HZ MULT .10 - 650.0 1.00
33 SPEED DP XXXXX, XXX.X, XXXXX
XX.XX,X.XXX,.XXXX
34 LOAD MLT 95 - 139% 100%
35 CONTRAST LOW, MED, HIGH MED
36 SLEEP TH .00 - 360.0 Hz .00 Hz
37 SLEEP DL 0.0 - 300.0 SEC 30.0 SEC
39 TB5 MIN .00 - 360.0 Hz (NOTE 2) .00 Hz
40 TB5 MAX .00 - 360.0 Hz 60 (NOTE 2) .00 Hz
41 AIN FLTR 0.01 - 10.0 SEC 0.02 SEC
42 TB10A OUT NONE, 0-10V, 2-10V NONE
43 @TB10A 3.00 - 360.0 HZ (NOTE 2) 60.00 Hz
44 TB10B OUT NONE, 0-10V, 2-10V NONE
45 @TB10B 10 - 200% 125%
47 TB13A NONE, 0-10VDC, 4-20MA, NONE
SPEED #1, LOC SEL,
DEC FREQ
48 TB13B NONE, 0-10VDC, 4-20MA, NONE
SPEED #2, INC FREQ,
JOG FWD, JOG REV
49 TB13C NONE, 0-10VDC, 4-20MA, NONE
SPEED #3, LOC SEL,
RUN REV, STRT REV
50 TB13D EXT FAULT, EXT EXT FAULT
/FAULT, EXT CLEAR
NOTE 2: MAX LIMIT IS 650 Hz ON UNITS WITH HIGH FREQUENCY SOFTWARE.