44
NOTE 1: REFER TO SECTION 18.0 - DESCRIPTION OF PARAMETERS.
NOTE 2: MAX LIMIT IS 650 Hz ON UNITS WITH HIGH FREQUENCY SOFTWARE.
NOTE 3: IF LINE VOLTS IS SET TO "LOW" (OR SET TO “AUTO” AND THE INPUT VOLTAGE
IS LOW), RANGE IS 25 - 150%.
PARAMETER MENU
PARAM. PARAMETER RANGE OF FACTORY
NUMBER NAME ADJUSTMENT DEFAULT
16 CURRENT 25 - 180% (NOTE 3) 180%
17 MOTOR OL 25 - 100% 100%
18 BASE 20.00 - 360.0 Hz (NOTE 2) 60.00 Hz
19 FX BOOST .0 - 30.0% NOTE 1
20 AC BOOST .0 - 20.0% 0.0%
21 SLIP COMP .0 - 5.0% 0.0%
*22 TORQUE CONSTANT, VARIABLE CONSTANT
CT/NO CMP
23 CARRIER 2.5, 6, 8, 10, 12, 14 kHz 2.5 kHz
25 START NORMAL, POWER-UP, NORMAL
AUTO RE-, RE-BRAKE
26 STOP RAMP, COAST COAST
27 ROTATION FORWARD, REVERSE, FORWARD
FWD&REV, FWD@LOC
28 AUTO/MAN AUTO, MANUAL, BOTH BOTH
29 MANUAL KEYPAD, 0-10 VDC KEYPAD
30 CONTROL LOCAL, REMOTE, BOTH LOCAL
31 UNITS HERTZ, RPM, % HZ, HERTZ
/SEC, /MIN, /HR, GPH, NONE