2.0 MICRO SERIES SPECIFICATIONS
Storage Temperature -20° to 70° C
Ambient Operating Temperature Chassis -10° to 55° C
(With 2.5 and 8 kHZ carrier, Type 1 (IP 31) -10° to 50° C
derate for higher carriers) Type 4 (IP 65) -10° to 40° C
Type 12 (IP 54) -10° to 40° C
Ambient Humidity Less than 95%
(non-condensing)
Maximum Altitude 3300 feet (1000 meters)
above sea level
Input Line Voltages 240/120 Vac, 240/200 Vac,
480/400 Vac, and 590/480 Vac
Input Voltage Tolerance +10%, -15%
Input Frequency Tolerance 48 to 62 Hz
Output Wave Form Sine Coded PWM
Output Frequency 0-120 Hz, Optional up to 1000 Hz
Carrier Frequency 2.5 kHz to 14 kHz
Frequency Stability +/-0.00006%/ C
Service Factor 1.00
Efficiency > 97% throughout speed range
Power Factor (Displacement) > 0.96
Overload Current Capacity 150% of drive output rating
for one minute
180% of drive output rating
for 30 seconds
Speed Reference Follower 0-10 VDC, or 4-20 mA
Control Voltage 15 VDC
Analog Outputs 0 - 10 VDC, or 2 - 10 VDC
Proportional to speed or load
Digital Outputs Form C relay: 2 A at 28 VDC or
120 Vac
Open-collector outputs:
40 mA at 30 VDC
3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Leeson SPEEDMASTER MICRO Series and is the answer not in the manual?

Leeson SPEEDMASTER MICRO Series Specifications

General IconGeneral
BrandLeeson
ModelSPEEDMASTER MICRO Series
CategoryInverter
LanguageEnglish

Related product manuals