Figure 5: Control Source Examples
ID Control Source Panics
Backup
Cue
Comments
Dimmer
Number
DMXA P DMXB P Analog
Channel
P Collage Area,
Zone
1 2
1 1 X X
DMXA -1 HTP with backup cue.
Panic 2 when active.
2 50 X
DMXB-50 HTP with backup cue.
3 P1 X
Analog input 1 HTP with backup
cue.
4 Area 1, Zn-001 X
Collage Area 1, Zn-001 HTP with
backup cue.
5 3 < P3
DMXA-3 when any DMX
multiplex input present. Analog
input 3 without DMX multiplex.
6 4 + 4 X
DMXA-4 HTP with DMXB-4 HTP
with backup cue.
7 P4 + Area 1, Zn-005
Analog input 4 HTP with Area 1,
Zn-005.
8
Nothing, dimmer always zero.
9 9 + P4
DMXA-9 HTP with analog input
4.
10 10 <TC1 Area 2, Zn-006
DMXA-10 when TC1 is on,
Collage Area 2, Zn-006 when TC1
is off.
11 20 + 30 + P11 + Area 2, Zn-011
DMXA-20 HTP with DMXB-30
HTP with analog input 11, HTP
with Collage Area 2, Zn-011.
12 12 < 12
DMXA-12 when DMXA link
present, otherwise DMXB-12.
13 P13 <TC3 Area 3, Zn-013
Analog input 13 when TC3 is on,
Collage Area 3, Zn-013 when TC3
is off.
14 14 >TC4 14
DMXB-14 when Take Control 4 is
on, otherwise DMXA-14.
15 P10 < Area 3, Zn-014
Analog input 10 when any DMX
multiplex present, Collage Area 3,
Zn-014 when DMX multiplex is
absent.
16 4
DMX4 when DMXA is present,
otherwise zero.
DX3 Manual 12