5-10 Maintenance
5. Close the door of the robot unit.
6. Put the robot unit in operation with the E-Link.
Prepare the MQC-C Reagent Solution
Safety data sheets and specifications of the MQC-C reagent are available at www.Lely.
com
The shelf lifetime of the MQC-C reagent solution is 3 months.Store the MQC-C reagent
solution in a closed container at a temperature of 4 to 30 ºC (29 to 86 ºF). Do not store
the MQC-C solution in the central unit.
At Lely consumables a large container for mixing the MQC-C reagent solution can be
ordered.
If necessary, prepare the MQC-C reagent solution:
1. Use a mixing container that can be closed.
2. Make sure the mixing container is empty.
3. Clean the mixing container with hot water.
4. Make sure the expiration date of the MQC-C reagent concentrate has not passed.
5. Remove the cap of the mixing container.
6. The ratio of potable water to MQC-C reagent concentrate is 15 to 1:
1. First add 15 parts of potable water.
2. Then add 1 part of MQC-C reagent concentrate.
7. Install the cap of the mixing container.
8. Shake the mixing container for 5 seconds and make sure the solution is mixed thoroughly.
9. Make sure there is a spare bottle of MQC-C reagent concentrate available. If not, order a new one.
Fill the Reagent Container
1. Open the door of the robot unit.
in n o vato rs in agriculture

Table of Contents

Other manuals for LELY ASTRONAUT A4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LELY ASTRONAUT A4 and is the answer not in the manual?

LELY ASTRONAUT A4 Specifications

General IconGeneral
BrandLELY
ModelASTRONAUT A4
CategoryRobotics
LanguageEnglish