CBX40UHV
3
OUTDOOR
SENSOR
DISCHARGE
AIR SENSOR
HEAT
1234
COOL
1234
DELAY
1234
ADJUST
NORM +
HUMIDIFICATION
SMART AUTO
EVENHEAT
1234
BLOWER
ONLY CFM
100
115
130
85
CUT FOR OPTION
Y1Y2
2STAGE
COMPR
RO
HEAT
PUMP
RDS
DEHUM
OR
HARMONY
FUTURE
USE
J7
J8
J9
J10
J5
J4
J11
W1 W2 G Y2 Y1 C R DH H L O DS
W3
FACTORY
JUMPER
FUSE 3 AMP
F1
XFMR
24V
24 VAC
COM
3
6
9
1
4
7
XFM LINE
7SEGMENT
LED DISPLAY
DEHUMIDIFICATION
HARMONY LINK
(JUMPERS R to DS)
HEAT PUMP LINK
(JUMPERS R to O)
2STAGE
COMPRESSOR LINK
(JUMPERS Y1 to Y2)
ONBOARD LINK
OPTION SELECTION
1
CBX40UHV JUMPER & LINK GUIDE
CUT ONBOARD LINK (SOLDER TRACE)
COMPLETELY
THROUGH BOTH LAYERS ON THE CONTROL BOARD
1
COOLING MODE
BLOWER RAMPING
DELAY
PROFILE #3
OFF82%100%OFF
CLG
HP
DELAY
PROFILE #2
OFF100%100%OFF
OFF30sOFF100%100% OFF
DELAY
PROFILE #1
OFF100%OFF
DELAY
PROFILE #4
OFF50%82%
100%50%OFF
*
(COOLING MODE UNLESS NOTED)
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
RDS
DEHUM
or
NO HARMONY ZONING
OR NO
COMFORTSENSE 7000
W/ DS CONNECTION
DO NOT CUT
HARMONY ZONING
OR
C0MFORTSENSE 7000
W/ DS CONNECTION
CUT LINK
HARMONY
RDS
DEHUM
or
HARMONY
1
A/C UNIT
HEAT PUMP UNIT
R0
HEAT
PUMP
R0
HEAT
PUMP
1
DO NOT CUT CUT LINK
2 STAGE
COMPR
1STG COMPRESSOR
2STG COMPRESSOR
Y1Y2
1
DO NOT CUT
CUT LINK
*
*
*
2 STAGE
COMPR
Y1Y2
*
HUMIDIFICATION MODE
SMART MODE
”H” ENABLED WHEN
HEAT ACTIVE
(HP or ELECT. HT)
AUTO MODE
”H” ENABLED WHEN
BLOWER ACTIVE
& NO CLG
OR DEHUM
HUMIDIFICATION MODE
24VAC OUTPUT ON ”H”
FOR HUMIDIFIER OR
ACCESSORY INTERLOCK
SMART
AUTO
SMART
AUTO
FACTORY DEFAULT SETTING
*
COOLING MODE
BLOWER SPEED
HIGH
SPEED
MEDIUMLOW
SPEED
LOW
SPEED
1
2
3
4
MEDIUMHIGH
SPEED
*
1
2
3
4
1
2
3
4
1
2
3
4
(COOLING & HP MODE)
STANDARD
HEAT MODE
(STAGED BY TSTAT)
STANDARD HEAT MODE
(DEFAULT)
85
110
115
130
HEATING MODE
BLOWER SPEED
*
(ELECTRIC HT MODE)
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
LOW
SPEED
MEDIUMLOW
SPEED
MEDIUMHIGH
SPEED
HIGH
SPEED
NORM
+
NORM
+
NORM
+
BLOWER
ADJUST SELECTION
NORMAL
(+ 10%)
SETTING
(10%)
SETTING
*
*
EVENHEATER
MODE
85
DEGREE TARGET
DISCHARGE
TEMPERATURE
100
DEGREE
TARGET
115
DEGREE
TARGET
130
DEGREE
TARGET
85
110
115
130
ENABLED WITH OPTIONAL
DISCHARGE AIR SENSOR
85
110
115
130
85
110
115
130
85
110
115
130
PUSH
BUTTON
HIGH
SPEED
(100%)
MEDIUMHIGH
SPEED
(70%)
LOW
SPEED
(28%)
* MEDIUMLOW
SPEED
(38%)
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
CONTINUOUS FAN
MODE BLOWER SPEED
IMPORTANT: USE CARE WHEN CUTTING LINKS TO
PREVENT DAMAGE TO CONTROL.
Figure 11. CBX40UHV−XXX−230−6−01

Other manuals for Lennox CBX40UHV Series