CBX40UHV
OUTDOOR
AIR SENSOR
HEAT
1234
COOL
1234
DELAY
123 4
ADJUST
NORM +
HUMIDIFICATION
SMART
AUTO
EVENHEAT
1234
BLOWER
ONLY CFM
100
115
130
85
Y1Y2
2STAGE
COMPR
RO
HEAT
PUMP
RDS
DEHUM
OR
C
W1
W2
G
Y2
Y1
C
R
DH
H
L
O
DS
W3
FACTORY
JUMPER
FUSE 3 AMP
XFMR 24V
24 VAC
COM
3
6
9
1
4
7
XFMR LINE
G
7SEGMENT LED
DEHUMIDIFICATION
HARMONY LINK
(JUMPERS R to DS)
HEAT PUMP LINK
(JUMPERS R to O)
2STAGE
COMPRESSOR LINK
(JUMPERS Y1 to Y2)
ONBOARD LINK
OPTION SELECTION
1
CBX32MV / CBX40UHV
JUMPER & LINK GUIDE
CUT ONBOARD LINK (SOLDER TRACE) COMPLETELY
THROUGH BOTH LAYERS ON THE CONTROL BOARD
1
COOLING BLOWER RAMPING
DELAY
PROFILE #3
OFF82%100%OFF
CLG
HP
DELAY
PROFILE #2
DELAY
PROFILE #1
OFF100%OFF
DELAY
PROFILE #4
OFF50%82%
100%50%OFF
*
(COOLING MODE UNLESS NOTED)
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
*
HUMIDIFICATION MODE
SMART MODE
”H” ENABLED WHEN
HEAT ACTIVE
(HP or ELECT. HT)
AUTO MODE
”H” ENABLED WHEN
BLOWER ACTIVE
& NO CLG
OR DEHUM
HUMIDIFICATION MODE
24VAC OUTPUT ON ”H”
FOR HUMIDIFIER OR
ACCESSORY INTERLOCK
SMART
AUTO
SMART
AUTO
FACTORY DEFAULT SETTING
*
COOLING MODE
BLOWER SPEED
HIGH
SPEED
MEDIUMLOW
SPEED
LOW
SPEED
1
2
3
4
MEDIUMHIGH
SPEED
*
1
2
3
4
1
2
3
4
1
2
3
4
(COOLING & HP MODE)
STANDARD
HEAT MODE
(STAGED BY TSTAT)
STANDARD HEAT MODE
(DEFAULT)
85
110
115
130
HEATING MODE
BLOWER SPEED
*
(ELECTRIC HT MODE)
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
LOW
SPEED
MEDIUMLOW
SPEED
MEDIUMHIGH
SPEED
HIGH
SPEED
NORM
+
NORM
+
NORM
+
BLOWER
ADJUST SELECTION
NORMAL
(+ 10%)
SETTING
(10%)
SETTING
*
*
EVENHEATER
MODE
85
DEGREE TARGET
DISCHARGE
TEMPERATURE
100
DEGREE
TARGET
115
DEGREE
TARGET
130
DEGREE
TARGET
85
110
115
130
ENABLED WITH OPTIONAL
DISCHARGE AIR SENSOR
85
110
115
130
85
110
115
130
85
110
115
130
PUSH
BUTTON
HIGH
SPEED
(100%)
MEDIUMHIGH
SPEED
(70%)
LOW
SPEED
(28%)
*
MEDIUMLOW
SPEED
(38%)
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
CONTINUOUS FAN
BLOWER SPEED
IMPORTANT: USE CARE WHEN CUTTING LINKS TO
PREVENT DAMAGE TO CONTROL.
2
5
8
P8
L1
L2
L2
L1
INDOOR
BLOWER
POWER
EARTH
INDOOR BLOWER
SIGNAL
4
5
6
12 3
A92
INTEGRATED
CONTROL
OUTDOOR UNIT
LINK
I +
I
I + I
R
C
I + I
R
C
THERMOSTAT
HUMIDITROL
DH
DISCHARGE
AIR SENSOR
HARMONY
RDS
DEHUM
or
NO HARMONY ZONING
OR NO
COMFORTSENSE 7000
W/ DS CONNECTION
DO NOT CUT
HARMONY ZONING
OR
C0MFORTSENSE 7000
W/ DS CONNECTION
CUT LINK
HARMONY
RDS
DEHUM
or
HARMONY
1
A/C UNIT
HEAT PUMP UNIT
R0
HEAT
PUMP
R0
HEAT
PUMP
1
DO NOT CUT
CUT LINK
2 STAGE
COMPR
1STG COMPRESSOR
2STG COMPRESSOR
Y1Y2
1
DO NOT CUT
CUT LINK
*
*
*
2 STAGE
COMPR
Y1Y2
OFF100%100%OFF
OFF30sOFF100%100% OFF
Figure 12. Air Handler Configuration (CBX40UHV−XXX−230−6−02 or higher)

Other manuals for Lennox CBX40UHV Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lennox CBX40UHV Series and is the answer not in the manual?

Lennox CBX40UHV Series Specifications

General IconGeneral
BrandLennox
ModelCBX40UHV Series
CategoryAir Handlers
LanguageEnglish

Related product manuals