EasyManuals Logo

Lennox CLIMATIC 50 User Manual

Lennox CLIMATIC 50
90 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #3 background imageLoading...
Page #3 background image
1
CLIMATIC 50, user manual – Chillers ranges CL50-CHILLERS/IOM
/
0906-E
1
TABLE OF CONTENTS
Page
INTRODUCTION........................................................................................................... 2
WIRING CONNECTIONS AND COMMUNICATION
Warning.................................................................................................................................3
CLIMATIC™ 50 Controller ....................................................................................................3
Climatic™ 50 controller – option DC50 remote connection...................................................4
Communication BMS ............................................................................................................5
Communication Master/Slave ...............................................................................................7
STANDARD CONTROL FEATURES
Scheduling ............................................................................................................................9
Anticipation – Heat pump mode only ...................................................................................10
Change over – Reversible units ...........................................................................................11
Evaporator pumps control ....................................................................................................12
Thermostat – Set point calculate..........................................................................................14
Thermostat – Control principle .............................................................................................15
Compressors control ............................................................................................................17
High pressure unloading ......................................................................................................18
Defrost – Heat pump ............................................................................................................19
Driving the electronic expansion valve.................................................................................21
Condensing fans control ......................................................................................................23
Customized Input / Output (BE.50) ......................................................................................25
Free-cooling .........................................................................................................................26
Energy recovery...................................................................................................................27
FAULT CODES
GENERAL FAULTS
Chilled water temperature, out of range.................................................................29
Insufficient water flow rate......................................................................................30
Communication with the extension board .............................................................31
Communication with the slave board .....................................................................32
REFRIGERATION CIRCUITS FAULTS
Low pressure cut out..............................................................................................33
Evaporator freezing protection...............................................................................34
Faults probes and sensors.....................................................................................35
COMPRESSOR FAULTS
Compressor electrical protection............................................................................36
High pressure too high...........................................................................................37
MISCELLAENOUS FAULTS
Insufficient flow rate provided by the pump............................................................38
Fans circuit breakers open.....................................................................................39
Pump circuit breaker open.....................................................................................40
CLIMATIC™50 Input/ Output MAPPING ................................................................... 41
CONTROL INTERFACE AND DISPLAYS .................................................................. 45
DC 50 CONFORT DISPLAY........................................................................................ 46
DS 50 SERVICE DISPLAY.......................................................................................... 56
DS 50 MENU TREE ECOLOGIC / ECOMAX RANGE ................................................ 66
FAULTS CODES ......................................................................................................... 78
BMS Points ................................................................................................................. 80
ModBus..................................................................................................................80
LonWorks...............................................................................................................84

Other manuals for Lennox CLIMATIC 50

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lennox CLIMATIC 50 and is the answer not in the manual?

Lennox CLIMATIC 50 Specifications

General IconGeneral
BrandLennox
ModelCLIMATIC 50
CategoryChiller
LanguageEnglish

Related product manuals