Menu Description 4thdigit 3rddigit 2nddigit 1stdigit R/W/Z Min Std Max
2271
setpointofdehumidification Sp.Deh. R/W/Z 0 10 100
2272
setpointofhumidification Sp.Hum. R/W/Z 0 0 100
2281
activationoftcbfeature Mode R/W 0 0 1
2282
stateof'g'signal ‐GR001
2283
stateof'b'signal ‐BR001
2284
stateof'y1'signal ‐Y1 R 0 0 1
2285
stateof'y2'signal ‐Y2 R 0 0 1
2286
stateof'w1'signal ‐W1 R 0 0 1
2287
stateof'w2'signal ‐W2 R 0 0 1
2311
stateofconfiguration Config. R 0 0 21
2312
states
ofmanagement Status R 23 23 62
2313
stateoftheauxiliarycontact StateiD R 0 0 1
2314
stateoftherelay Relay R 0 0 1
2315
countvalueofoperatingtime RunTime R 0 0 9999
2316
setpointforactivationoperationofcomponent Enabled R/W/Z 0 1 1
2317
setpointforactivationoperationinroomcontroldeadzone DeadZ. R/W/Z 0 1 1
2318
temperaturethresholdforactivationnightrefreshmentfunction NightEco R/W 8 22 35
2321
stateofconfiguration Config. R 0 0 21
2322
statesof
management Status R 23 23 62
2323
stateofthesafetycontactofinverter StateiD R 0 0 1
2324
speedpercentagecalculatedfortheinverter Inverter R 0 0 100
2325
speedpercentagesendtotheinverter Output R 0 0 24000
2326
calculatedvalueofairfloworevaporatorflowswitch Flow R 0 0 24000
2327
choiceofspeedfunction Function R/W 0 0 2
2328
nominalthresholdforairflowcontrol FlowH. R/W 0 85 100
2329
lowthresholdforairflowcontrol
FlowL. R/W 0 33 100
2331
stateofconfiguration Config. R 0 0 21
2332
valueofdifferentialpressuresensoronairflow DeltadP R 0 0 1000
2333
airflowthresholdalarm AirFlow R/W 0 25 1000
2334
filtersmissingthresholdalarm Missing R/W 0 50 1000
2335
dirtyfiltersthresholdalarm Dirty R/W 50 250 1000
2341
stateofsmokedetectioncontact
User Blower Safety
FireiD R 0 0 1
2411
stateofconfiguration Config. R 0 0 21
2412
valueoftheevaporatingpressureortemperature Evap. R 1 120
2413
value
ofthesuctiontemperature Suction R 99,9 0 99,9
2414
valueofthecondensingpressureortemperature Cond. R 1 145
2415
valueoftheliquidtemperature Liquid R 99,9 0 99,9
2416
lowpressure,stateofthesafety LowP. R 0 0 1
2417
stateofthereversingvalve R.Valve R 0 0 1
2418
speedpercentagecalculatedfortheinverter Inverter R 0 0 100
2419
speedpercentagesendtotheinverter Output R 0 0 1
2421
stateofconfiguration Config. R 0 0 21
2422
statesofmanagement Status R 23 23 62
2423
stateoftheauxiliarycontact StateiD R 0 0 1
2424
stateoftherelay Relay R 0 0 1
2425
countvalueofoperatingtime RunTime R 0 0 9999
User
User
User
User
User
User
User
Control
Control
Blower
Blower
Blower
Compressor
Compressor Circ.1Comp.1
Tcb
Fan
Speed
AirFlow
Circuit1
HumiditySp
CLIMATICRT_UNITARYIOM1508E .84.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lennox CLIMATIC series and is the answer not in the manual?

Lennox CLIMATIC series Specifications

General IconGeneral
ConnectivityWi-Fi
CompatibilityLennox HVAC systems
User InterfaceTouchscreen
Remote AccessYes, via app
Energy ManagementEnergy-saving modes
DisplayColor
Programmability7-day programmable

Related product manuals