ComfortSenseE 7000 Touchscreen Thermostat / Page 3
FEATURES
TOUCHSCREEN DISPLAY (CONTINUED)
Options Screen
− Maintenance reminders (REMINDERS)
− User configuration (USER SETTINGS)
− Installer configuration (INSTALLER SETTINGS)
− Clean screen button (CLEAN)
Reminders
Reminders notify user when routine maintenance is
required.
− Filter Media (REPLACE FILTER MEDIA)
− Ultraviolet Lamp (REPLACE UV LAMP)
− Humidifier Pad (REPLACE HUM PAD)
− System Maintenance (ROUTINE SYS CHECK−UP)
− PureAir™ Maintenance (REPLACE METAL INSERT)
−(REMINDERS) See Installer Settings
Two custom reminders can also be set (see Installer
Settings)
User can turn on and off individual reminders (default is
OFF).
Reminders can be set to chronological time or equipment
run time from 1 to 24 months.
Reminders can be reset (snooze) at any time.
Reminders that are due are displayed on the HOME
screen.
In case of power interruption:
− If the lithium battery is charged, the chronological time
or total accumulated equipment run time (depending
on reminder setting) is maintained.
− If the lithium battery is not charged, due dates for
reminders are maintained.
Touchscreen Cleaning
Pressing CLEAN locks the thermostat for 30 seconds to
allow cleaning of the screen.
A countdown shows remaining time left.
SPECIFICATIONS
NOTE − For use with residential equipment only.
Order No. − Y0349
Temperature Setting Range
Heating − 45 to 90°F
Cooling − 45 to 99°F
Humidity Settings
− Operating range − 10 to 90% relative humidity
− Humidity setpoint (Humidification mode) − 10 to 45%
relative humidity
− Humidity setpoint (Dehumidification mode) − 35 to 60%
relative humidity
Power Supply
24VAC (18 to 30VAC maximum), 60Hz
Clock Accuracy
± 10 minutes per year
Terminals
4 heat / 2 cool multi−stage
R, H, W1, W2, O, L, Y1, Y2, G, D, B, C, T, T
Dimensions (H x W x D)
5−7/8 x 8−1/2 x 1−1/4 in. (149 x 216 x 31 mm)
Backup
Non−volatile memory maintains all programming in the
event of a power outage.
Lithium battery (furnished) provides backup for
chronological (clock) time in case of power failure.
OPTIONS
Outdoor Temperature Sensor
When installed outdoors, sensor
(X2658) allows thermostat to display
outdoor temperature.
NOTE − Sensor is required for dual fuel
operation if thermostat controls dual
fuel system operation. Also required
with Humiditrol
®
applications and
Humidity Settings / Humidity / Dewpoint
operation (see Installer Settings).