EasyManua.ls Logo

Lennox ComfortSense 7000

Lennox ComfortSense 7000
8 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ComfortSenseE 7000 Touchscreen Thermostat / Page 4
FEATURES
User Settings
DATE / TIME
Set Month, Day, Year, Hour and Minute
F / C
Fahrenheit (default) or Celsius
12 OR 24 HOUR
12 (default) or 24 hour clock
EVENTS DAILY 2 OR 4
Number of schedule periods (default 4) per day.
DISPLAY INFO
(View alternates)
OUTDOOR TEMP
Information display shows outdoor temperature
if equipped with Optional Outdoor Temperature
Sensor (default is off)
INDOOR RH
Indoor Relative Humidity (default is off)
HUMIDITROL ADJUST
MAX, MID, MIN (if equipped).
FAN CIRCULATE
See Fan Modes on previous page for % settings
available.
COOLING LIMIT
Cooling Limit, 45°F (default) adjustable (45 to 90°F)
HEATING LIMIT
Heating Limit, 90°F (default) adjustable (90 to 45°F)
SECURITY LOCK
Prevents tampering, 3−digit security code
HUMIDITY SETTING
Humidity setpoint 45% (default), adjustable (15% to
45%)
Dehumidify setpoint 50% (default), adjustable (35% to
60%)
BACKLIGHT SETTINGS
Power save (default) or continuous
BACKLIGHT INTENSITY
100% (default) adjustable (20 to 100%)

Related product manuals