CBX32MV / Page 9
SPECIFICATIONS
General Data Model Number CBX32MV-048 CBX32MV-060 CBX32MV-068
Nominal tonnage 4 5 5+
Refrigerant R-410A R-410A R-410A
Connections
in.
Suction / vapor (o.d.) line - sweat 7/8 7/8 1-1/8
Liquid line (o.d.) - sweat 3/8 3/8 3/8
Condensate drain - in. (fpt) (2) 3/4 (2) 3/4 (2) 3/4
Indoor
Coil
Net face area - ft.
2
7.22 7.22 7.77
Tube outside diameter - in. 3/8 3/8 3/8
Number of rows 3 3 3
Fins per inch 12 12 12
Blower Data Wheel nominal diameter x width - in. 12 x 9 12 x 9 15 x 9
Motor output - hp 1 1 1
Filters
1
Number and size - in. (1) 20 x 24 x 1 (1) 20 x 24 x 1 (1) 20 x 25 x 1
Shipping Data - 1 Package - lbs. 212 212 244
ELECTRICAL DATA
Voltage - phase - 60hz 208/230V-1ph 208/230V-1ph 208/230V-1ph
2
Maximum overcurrent protection (unit only) 20 20 20
3
Minimum circuit ampacity (unit only) 11 11 11
CONTROLS
iComfort
®
S30 Thermostat 12U67 12U67 12U67
iComfort Wi-Fi
®
Thermostat 10F81 10F81 10F81
ComfortSense
®
7500 Thermostat 13H14 13H14 13H14
4
Remote Outdoor Sensor (for dual fuel and Humiditrol
®
) X2658 X2658 X2658
5
Discharge Temperature Sensor 88K38 88K38 88K38
OPTIONAL ACCESSORIES - ORDER SEPARATELY
Circuit Breaker Cover Kit 82W01 82W01 82W01
Downow Additive Base 44K15 44K15 44K15
Electric Heat See Electric Heat Data tables
Healthy Climate
Germicidal Light
UVC-24V (24V) X9423 X9423 X9423
Shielding Bafe (required) Y5172 Y5172
Y5172
UVC-41W-S (110/230v-1 ph) X9424 X9424 X9424
Shielding Bafe (required) Y5171 Y5171 Y5171
Horizontal Support Frame Kit 56J18 56J18 N/A
Hot Water Heat Kit 90W84 90W84 90W84
Side Return Unit Stand (Upow) 45K32 45K32 N/A
Single-Point Power Source Control Box 21H39 21H39 21H39
Wall Hanging Bracket Kit (Upow) 45K30 45K30 45K30
1
Disposable frame type lter.
2
HACR type circuit breaker or fuse.
3
Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. Use wires suitable for at least 167°F.
4
Remote Outdoor Temperature Sensor is used with conventional (non-iComfort
®
-enabled) outdoor units (sensor is furnished with iComfort
®
-enabled outdoor units).
Allows the thermostat to display outdoor temperature. Required in dual-fuel and Humiditrol
®
applications.
5
Optional for EvenHeater
®
electric heat operation and service diagnostics.
REPLACEMENT CIRCUIT BREAKERS
Voltage Description Catalog No.
208/240V - 1 Phase 25 amp, 2 pole 41K13
30 amp, 2 pole 17K70
35 amp, 2 pole 72K07
40 amp, 2 pole 49K14
45 amp, 2 pole 17K71
50 amp, 2 pole 41K12
60 amp, 2 pole 17K72
208/240V - 3 Phase 30 amp, 3 pole 64W47
35 amp, 3 pole 41K14
40 amp, 3 pole 41K16
45 amp, 3 pole 18M86
50 amp, 3 pole 41K15
60 amp, 3 pole 41K17
9 of 44 B17-0056