EasyManuals Logo

Lennox DAVE LENNOX SIGNATURE CBX32MV User Manual

Lennox DAVE LENNOX SIGNATURE CBX32MV
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #9 background imageLoading...
Page #9 background image
CBX32MV / Page 9
SPECIFICATIONS
General Data Model Number CBX32MV-048 CBX32MV-060 CBX32MV-068
Nominal tonnage 4 5 5+
Refrigerant R-410A R-410A R-410A
Connections
in.
Suction / vapor (o.d.) line - sweat 7/8 7/8 1-1/8
Liquid line (o.d.) - sweat 3/8 3/8 3/8
Condensate drain - in. (fpt) (2) 3/4 (2) 3/4 (2) 3/4
Indoor
Coil
Net face area - ft.
2
7.22 7.22 7.77
Tube outside diameter - in. 3/8 3/8 3/8
Number of rows 3 3 3
Fins per inch 12 12 12
Blower Data Wheel nominal diameter x width - in. 12 x 9 12 x 9 15 x 9
Motor output - hp 1 1 1
Filters
1
Number and size - in. (1) 20 x 24 x 1 (1) 20 x 24 x 1 (1) 20 x 25 x 1
Shipping Data - 1 Package - lbs. 212 212 244
ELECTRICAL DATA
Voltage - phase - 60hz 208/230V-1ph 208/230V-1ph 208/230V-1ph
2
Maximum overcurrent protection (unit only) 20 20 20
3
Minimum circuit ampacity (unit only) 11 11 11
CONTROLS
iComfort
®
S30 Thermostat 12U67 12U67 12U67
iComfort Wi-Fi
®
Thermostat 10F81 10F81 10F81
ComfortSense
®
7500 Thermostat 13H14 13H14 13H14
4
Remote Outdoor Sensor (for dual fuel and Humiditrol
®
) X2658 X2658 X2658
5
Discharge Temperature Sensor 88K38 88K38 88K38
OPTIONAL ACCESSORIES - ORDER SEPARATELY
Circuit Breaker Cover Kit 82W01 82W01 82W01
Downow Additive Base 44K15 44K15 44K15
Electric Heat See Electric Heat Data tables
Healthy Climate
Germicidal Light
UVC-24V (24V) X9423 X9423 X9423
Shielding Bafe (required) Y5172 Y5172
Y5172
UVC-41W-S (110/230v-1 ph) X9424 X9424 X9424
Shielding Bafe (required) Y5171 Y5171 Y5171
Horizontal Support Frame Kit 56J18 56J18 N/A
Hot Water Heat Kit 90W84 90W84 90W84
Side Return Unit Stand (Upow) 45K32 45K32 N/A
Single-Point Power Source Control Box 21H39 21H39 21H39
Wall Hanging Bracket Kit (Upow) 45K30 45K30 45K30
1
Disposable frame type lter.
2
HACR type circuit breaker or fuse.
3
Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. Use wires suitable for at least 167°F.
4
Remote Outdoor Temperature Sensor is used with conventional (non-iComfort
®
-enabled) outdoor units (sensor is furnished with iComfort
®
-enabled outdoor units).
Allows the thermostat to display outdoor temperature. Required in dual-fuel and Humiditrol
®
applications.
5
Optional for EvenHeater
®
electric heat operation and service diagnostics.
REPLACEMENT CIRCUIT BREAKERS
Voltage Description Catalog No.
208/240V - 1 Phase 25 amp, 2 pole 41K13
30 amp, 2 pole 17K70
35 amp, 2 pole 72K07
40 amp, 2 pole 49K14
45 amp, 2 pole 17K71
50 amp, 2 pole 41K12
60 amp, 2 pole 17K72
208/240V - 3 Phase 30 amp, 3 pole 64W47
35 amp, 3 pole 41K14
40 amp, 3 pole 41K16
45 amp, 3 pole 18M86
50 amp, 3 pole 41K15
60 amp, 3 pole 41K17
9 of 44 B17-0056
01/19/2017

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lennox DAVE LENNOX SIGNATURE CBX32MV and is the answer not in the manual?

Lennox DAVE LENNOX SIGNATURE CBX32MV Specifications

General IconGeneral
TypeVariable Speed Air Handler
RefrigerantR-410A
AirflowUp to 2000 CFM
Warranty10-Year Limited Warranty
Nominal Cooling Capacity1.5 - 5 Ton
Nominal Heating CapacityMatch with heat pump or furnace
Blower MotorVariable Speed ECM
FilterMERV 16

Related product manuals