CONTROL VARIABLES
FLEXYII_WSHP-IOM-1307-E - 71 -
Function
The Climatic
TM
60 has free inputs / outputs on the main board BM60 and the expansion board BE60 to
offer different possibilities to customize input / output for remote control of the unit.
Description
Free customized inoputs / outputs number depends on added option. Without any option, expansion
board BE60 is available with DCBO option.
Below, "not always available" means that some inputs/outputs could be used by options. Refer to the
electrical wiring diagram or to the CL60_IOM.
Digital outputs (dry contacts NO)
Maximum 2 free output contacts on BM60 :
BM_J14-NO7
Not always available
BM_J15-NO12
Not always available
Maximum 4 free output contacts on BE60
BE-J5-NO1
Not always available
BE-J6-NO2
always available
BE-J7-NO3
always available
BE-J8-NO4
always available
Functions can be set among followings:
Alarm
Alarm, General
Minor A
Alarm, Minor
Major A
Alarm, Major
Filter A
Alarm, Dirty filters or missing
Blower A
Alarm, Blower
Comp. A
Alarm, Circuit (Compressor)
Gas A
Alarm, Gas burner
Elec. A
Alarm, Electrical heaters
Frost. A
Alarm, Supply to low (Freeze protection)
Smoke A
Alarm, Smoke detection
Defrost
Circuit, Defrosting cycle requested or
activated (Compressor)
Heating
Control, Heating mode activated
Dead Z.
Control, Dead zone mode activated
Cooling
Control, Cooling mode activated
by BMS
BMS, Activated by BMS
Sched. A
Schedule, Mode A activated
Sched. B
Schedule, Mode B activated
Sched. C
Schedule, Mode C activated
Sched. D
Schedule, Mode D activated
Sched.BMS
Schedule, Mode BMS activated
Sched.Z0
Schedule, Zone 0 activated
Sched.Z1
Schedule, Zone 1 activated
Sched.Z2
Schedule, Zone 2 activated
Sched.Z3
Schedule, Zone 3 activated
Sched.Z4
Schedule, Zone 4 activated
Sched.Z5
Schedule, Zone 5 activated
Sched.Z6
Schedule, Zone 6 activated
Analog inputs (NTC probe or 4/20mA signal)
No analog input on BM60 :
Maximum 4 free analog inputs on BE60
BE_J9-B1
Not always available
BE_J9-B2
Not always available
BE_J10-B3
Not always available
BE_J10-B4
Not always available
Functions can be set among followings:
Power
Power of the unit (ON/OFF)
Ntc BMS
BMS, temperature (NTC) reading for BMS
Hr. BMS
BMS, relative humidity (4-20mA) reading for
BMS
Sp Temp.
Control set point, swift of the value (4mA=-5K,
20mA=+5K)
Sp F.Air
Fresh air set point, value (4mA=0%,
20mA=100%)
Sp Speed
Speed blower set point, value (4mA=low level,
20mA=nominal level)
T. Out.
Control, outside temperature by 4-20mA
sensor
T. Room
Control, room temperature by 4-20mA sensor
Hr. Out.
Control, outside relative humidity by 4-20mA
sensor
Hr. Room
Control, room relative humidity by 4-20mA
sensor

Table of Contents

Other manuals for Lennox Fhm 150

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lennox Fhm 150 and is the answer not in the manual?

Lennox Fhm 150 Specifications

General IconGeneral
BrandLennox
ModelFhm 150
CategoryHeat Pump
LanguageEnglish

Related product manuals