EasyManuals Logo

Lennox KGA Series User Manual

Lennox KGA Series
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #3 background imageLoading...
Page #3 background image
Page 3
OPTIONS / ACCESSORIES
Item Description
Model
Number
Catalog
Number
Unit Model No
092 102 120 150
CABINET
Coil Guards K1GARD20B-1 55W08 X X X X
Hail Guards K1GARD10B1 55W11 X X X X
Hinged Access Panels Factory O O O O
Horizontal Discharge Kit K1HECK00B-1 51W25 X X X X
Return Air Adaptor Plate (for L Series
®
and T-Class™ replacement) C1CONV10B-1 54W96 X X X X
CONTROLS
Commercial Controls L Connection
®
Building Automation System - - - X X X X
Smoke Detector - Supply or Return (Power board and one sensor) C1SNSR44B-1 53W80 X X X X
Smoke Detector - Supply and Return (Power board and two sensors) C1SNSR43B-1 53W81 X X X X
INDOOR AIR QUALITY
Air Filters
Healthy Climate
®
High Efciency Air Filters
20 x 25 x 2 (Order 4 per unit)
MERV 8 - C1FLTR15B-1 50W61 X X X X
MERV 13 - C1FLTR40B-1 52W41 X X X X
Replacement Media Filter With Metal Mesh
Frame (includes non-pleated lter media)
C1FLTR30B-1- Y3063
X X X X
Indoor Air Quality (CO
2
) Sensors
Sensor - Wall-mount, off-white plastic cover with LCD display C0SNSR50AE1L 77N39 X X X X
Sensor - Wall-mount, off-white plastic cover, no display C0SNSR52AE1L 87N53 X X X X
Sensor - Black plastic case with LCD display, rated for plenum
mounting
C0SNSR51AE1L 87N52 X X X X
Sensor - Wall-mount, black plastic case, no display, rated for
plenum mounting
C0MISC19AE1 87N54 X X X X
CO
2
Sensor Duct Mounting Kit - for downow applications C0MISC19AE1- 85L43 X X X X
Aspiration Box - for duct mounting non-plenum rated CO
2
sensors
(87N53 or 77N39)
C0MISC16AE1- 90N43 X X X X
UVC Germicidal Lamps
1
Healthy Climate
®
UVC Light Kit (208/230v-1ph) C1UVCL10B-1 54W62 X X X X
ELECTRICAL
Voltage 60 hz 208/230V - 3 phase Factory O O O O
460V - 3 phase Factory O O O O
575V - 3 phase Factory O O O O
Disconnect Switch 80 amp - C1DISC080B-1 54W56 OX OX OX OX
GFI Service Outlets LTAGFIK10/15 74M70 OX OX OX OX
1
Lamps operate on 110-230V single-phase power supply. Step-down transformer may be ordered separately for 460V and 575V units. Alternately, 110V power supply
may be used to directly power the UVC ballast(s)
NOTE - Catalog and model numbers shown are for ordering eld installed accessories.
OX - Congure To Order (Factory Installed) or Field Installed
O = Congure To Order (Factory Installed)
X = Field Installed

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lennox KGA Series and is the answer not in the manual?

Lennox KGA Series Specifications

General IconGeneral
BrandLennox
ModelKGA Series
CategoryAir Conditioner
LanguageEnglish

Related product manuals