OPTIONS / ACCESSORIES
Item
Model
Number
Catalog
Number
Unit Model Number
036 048 060 072 074
ECONOMIZER
Standard Economizer With Outdoor Air Hood (Sensible Control) (Not for Title 24)
Standard Economizer - Includes Barometric Relief Dampers
and Exhaust Hood
E1ECON30A-2- 90W59 OX OX OX OX OX
Standard Economizer - Includes Barometric Relief Dampers
and Exhaust Hood and Power Exhaust
Factory O O O O O
Standard Economizer - No Exhaust Option Factory O O O O O
High Performance Economizer With Outdoor Air Hood (Sensible Control)
(Approved for California Title 24 Building Standards / AMCA Class 1A Certied)
High Performance Economizer - Includes Barometric Relief
Dampers with Exhaust Hood
E1ECON17A-1 10U54 OX OX OX OX OX
High Performance Economizer - No Exhaust Option Factory O O O O O
Economizer Accessories
Horizontal Economizer Conversion Kit T1HECK00AN1 17W45 X X X X X
Economizer Controls (Not for Title 24)
Differential Enthalpy Order 2 - C1SNSR64FF1 53W64 OX OX OX OX OX
Sensible Control Sensor is Furnished Factory O O O O O
Single Enthalpy C1SNSR64FF1 53W64 OX OX OX OX OX
Global Control Sensor Field Provided Factory O O O O O
Building Pressure Control E1GPBK20C1 13J77 X X X X X
OUTDOOR AIR
Outdoor Air Dampers With Outdoor Air Hood
Motorized C1DAMP21A-1 15D17 OX OX OX OX OX
Manual C1DAMP11A-2 15D18 OX OX OX OX OX
POWER EXHAUST FAN
Standard Static
Note: Factory installed Power
Exhaust Fan includes Exhaust
Hood. Barometric Relief Dampers
without Exhaust Hood are required
(order separately).
Note: Field installed Power Exhaust
Fans do not include Exhaust Hood.
Barometric Relief Dampers with
Exhaust Hood are required (order
separately).
208/230V-1 or 3ph - C1PWRE10A-1P 79W87 OX OX OX OX OX
460V-3ph - C1PWRE10A-1G 79W88 OX OX OX OX OX
575V-3ph - C1PWRE10A-1J 79W89 OX OX OX OX OX
BAROMETRIC RELIEF
1
Barometric Relief Dampers with Exhaust Hood C1DAMP50A-1- 74W38 X X X X X
2
Barometric Relief Dampers without Exhaust Hood C1DAMP50A-2- 72W89 X X X X X
HUMIDITROL
®
CONDENSER REHEAT OPTION
Humiditrol Dehumidication Option Factory O O O O O
Humidity Sensor Kit, Remote mounted (required) C0SNSR31AE-1 17M50 X X X X X
1
Required when Economizer is factory installed (no exhaust option) with eld installed Power Exhaust Fan option.
2
Required when Economizer is factory installed with factory installed Power Exhaust Fan option.
NOTE - Catalog and model numbers shown are for ordering eld installed accessories.
OX - Congure To Order (Factory Installed) or Field Installed
O = Congure To Order (Factory Installed)
X = Field Installed