OPTIONS / ACCESSORIES
Item
Model
Number
Catalog
Number
Unit Model Number
036 048 060 072 074
INDOOR AIR QUALITY
Air Filters
Healthy Climate
®
High Efciency
Air Filters
Order 4 per unit
MERV 8 (16 x 20 x 2 in.) - C1FLTR15A-1- 54W20 OX OX
MERV 13 (16 x 20 x 2 in.) - T1FLTR40A-1- 52W37 OX OX
MERV 8 (20 x 20 x 2 in.) - C1FLTR15D-1- 54W21 OX OX OX
MERV 13 (20 x 20 x 2 in.) - C1FLTR40D-1- 52W39 OX OX OX
Replaceable Media Filter With
Metal Mesh Frame
(includes non-pleated lter media)
16 x 20 x 2 in. (Order 4) - K1FLTR30A-1 39W09 X X
20 x 20 x 2 in. (Order 4) - K1FLTR30A-2 44N60 X X X
Indoor Air Quality (CO
2
) Sensors
Sensor - Wall-mount, off-white plastic cover with LCD display C0SNSR50AE1L 77N39 X X X X X
Sensor - Wall-mount, off-white plastic cover, no display C0SNSR52AE1L 87N53 X X X X X
Sensor - Black plastic case with LCD display, rated for plenum
mounting
C0SNSR51AE1L 87N52 X X X X X
Sensor - Wall-mount, black plastic case, no display, rated for plenum
mounting
C0MISC19AE1 87N54 X X X X X
CO
2
Sensor Duct Mounting Kit - for downow applications C0MISC19AE1- 85L43 X X X X X
Aspiration Box - for duct mounting non-plenum rated CO
2
sensors (87N53 or 77N39)
C0MISC16AE1- 90N43 X X X X X
UVC Germicidal Lamps
1
Healthy Climate
®
UVC Light Kit (208/230v-1ph) C1UVCL10AN1- 50W90 OX OX OX OX OX
ROOF CURBS
Hybrid Roof Curbs, Downow
8 in. height C1CURB70A-1 11F50
X X X X X
14 in. height C1CURB71A-1 11F51 X X X X X
18 in. height C1CURB72A-1 11F52 X X X X X
24 in. height C1CURB73A-1 11F53 X X X X X
Adjustable Pitched Curb
14 in. height C1CURB55AT1 43W27 X X X X X
Transition Curb
Matches Energence
®
036-074 Units to existing L Series
®
Curbs E1CURB60A-1 20W06 X X X X X
CEILING DIFFUSERS
Step-Down - Order one RTD9-65S 13K60 X X X
RTD11-95S 13K61 X X
Flush - Order one FD9-65S 13K55 X X X
FD11-95S 13K56 X X
Transitions (Supply and Return) - Order one T1TRAN10AN1 17W53 X X X
T1TRAN20N-1 17W54 X X
1
Lamps operate on 110-230V single-phase power supply. Step-down transformer may be ordered separately for 460V and 575V units. Alternately, 110V power supply
may be used to directly power the UVC ballast(s).
NOTE - Catalog and model numbers shown are for ordering eld installed accessories.
OX - Congure To Order (Factory Installed) or Field Installed
O = Congure To Order (Factory Installed)
X = Field Installed