Specications – LRP16HP
General Data Model No. LRP16HP24LRP16HP36 LRP16HP48 LRP16HP60
Nominal Tonnage
Cooling /
Heating
Performance
Cooling Total capacity - Btuh 23,000 35,000 47,000 57,000
Total unit watts 1910 2910 3910 4950
1
SEER (Btuh/Watt) 16.0 16.016.
5.5
EER (Btuh/Watt) 12.0 12.012.
1.5
High Temp.
Heat
Total capacity - Btuh 22,000 34,000 46,000 56,000
Total unit watts 1791 2770 3740 4440
COP 3.60 3.60 3.60 3.70
HSPF (Region IV) 8.20 8.20 8.20 8.20
Low Temp.
Heat
Total capacity - Btuh 11,900 19,700 26,600 37,200
Total unit watts 1480 2530 3500 4250
COP 2.36 2.28 2.23 2.57
2
Sound Rating Number (dBA) 71 71 74 74
Refrigerant Type R-410A R-410A R-410A R-410A
Charge 5 lbs. 5 oz.8 lbs. 0 oz. 10 lbs. 8 oz.10 lbs. 8 oz.
Condensate drain size (fpt) - in. 3/43/4 3/
/4
Outdoor Coil Net Face Area - sq. ft. 16.3 15.518.
8.6
Tube diameter - in. 5/16 5/16 5/16 5/16
Number of Rows
Fins per in. 22 22 22 22
Outdoor Coil
Fan
Motor horsepower 1/21/2 1/
/2
Diameter - in. 22 22 24 24
Number of blades
Indoor Coil Net Face Area - sq. ft. 4.44.4 6.
.8
Tube Diameter - in. 5/16 3/83/8 3/8
Number of Rows
Fins per Inch 15 15 15 15
Indoor Blower Blower wheel size dia. x width - in. 10 x 6 10 x 8 10 x 10 12 x 9
Motor horsepower 1/21/2 3/
Net weight of basic unit - lbs. 425 460 540 555
Shipping weight of basic unit (1 Pkg.) - lbs. 430 465 545 560
Electrical characteristics (60 hz) 208/230V-1ph-60hz
1
AHRI to AHRI Standard 210/240:
Cooling Ratings - 95°F outdoor air temperature and 80°F db/67°F wb entering indoor coil air.
High Temperature Heating Ratings - 47°F db/43°F wb outdoor air temperature and 70°F entering indoor coil air.
Low Temperature Heating Ratings - 17°F db/15°F wb outdoor air temperature and 70°F entering indoor coil air.
2
Sound Rating Number rated in accordance with test conditions included in AHRI Standard 270.