EasyManua.ls Logo

Lennox Merit Series13HPD Units - User Manual

Lennox Merit Series13HPD Units
22 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
09/07 505,361M
*2P0907* *P505361M*
Page 1
2007 Lennox Industries Inc.
Dallas, Texas, USA
RETAIN THESE INSTRUCTIONS
FOR FUTURE REFERENCE
WARNING
Improper installation, adjustment, alteration,
service or maintenance can cause property damage,
personal injury or loss of life. Installation and
service must be performed by a qualified installer or
service agency.
CAUTION
Physical contact with metal edges and corners
while applying excessive force or rapid motion can
result in personal injury. Be aware of, and use
caution when working near these areas during
installation or while servicing this equipment.
IMPORTANT
The Clean Air Act of 1990 bans the intentional
venting of refrigerant (CFCs, HCFCs AND HFCs) as
of July 1, 1992. Approved methods of recovery,
recycling or reclaiming must be followed. Fines
and/or incarceration may be levied for
noncompliance.
INSTALLATION
INSTRUCTIONS
Merit
®
Series13HPD Units
1−½ to 5 TONS
HEAT PUMP UNITS
505,361M
09/07
Supersedes 504,943M
Table of Contents
Shipping and Packing List 1. . . . . . . . . . . . . . . . . . . . . .
13HPD Outdoor Unit 1. . . . . . . . . . . . . . . . . . . . . . . . . . .
Unit Dimensions 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
General Information 2. . . . . . . . . . . . . . . . . . . . . . . . . . .
Recovering Refrigerant from Existing System 4. . . . .
Disconnecting and Removing Old Outdoor Unit 5. . . .
Positioning New Outdoor Unit 5. . . . . . . . . . . . . . . . . . .
New or Replacement Refrigerant Line Set 6. . . . . . . .
Replacing Refrigerant Metering Device 8. . . . . . . . . . .
Brazing Connections 9. . . . . . . . . . . . . . . . . . . . . . . . . . .
Testing for Leaks 10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Evacuating the System 11. . . . . . . . . . . . . . . . . . . . . . . . .
Electrical Connections 12. . . . . . . . . . . . . . . . . . . . . . . . .
Start−Up Procedures 14. . . . . . . . . . . . . . . . . . . . . . . . . . .
Determining Charge Method 15. . . . . . . . . . . . . . . . . . . .
System Operation 17. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Defrost System 17. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Maintenance 18. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Homeowner Information 20. . . . . . . . . . . . . . . . . . . . . . . .
Start−Up and Performance Checklist 22. . . . . . . . . . . . .
Shipping and Packing List
1 − Assembled 13HPD outdoor unit
Check equipment for shipping damage. If you find any
damage, immediately contact the last carrier.
13HPD Outdoor Unit
The Lennox 13HPD Heat Pumps, which will also be
referred to in this instruction as the outdoor unit, uses
HCFC−22 refrigerant. This unit must be installed with a
matching indoor unit and line set as outlined in the Lennox
Engineering Handbook. This unit is designed for use in
check thermal expansion valve (CTXV) and fixed orifice
systems.
Litho U.S.A.
Question and Answer IconNeed help?

Do you have a question about the Lennox Merit Series13HPD Units and is the answer not in the manual?

Lennox Merit Series13HPD Units Specifications

General IconGeneral
BrandLennox
ModelMerit Series13HPD Units
CategoryHeat Pump
LanguageEnglish

Related product manuals