EasyManua.ls Logo

Lennox MPA018S4M-*P

Lennox MPA018S4M-*P
168 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
140
Error Code: F4
Description: OutdoorEEPROMerror.
General Note: PCBmainchipdoesnotreceivefeedbackfromEEPROMchip.EEPROM:aread-onlymemorywhosecontentscanbe
erasedandreprogrammedusingapulsedvoltage.ForthelocationofEEPROMchip,pleaserefertothebelowphotos.
OutdoorEEPROMmalfunction
Poweroff,thenrestarttheunit3minutes
later.
Yes
Doestheproblemstillexist?
Outdoor PCB(M3OC-30HRFN1-M)
Yes
ReplacetheoutdoormainPCB.

Table of Contents

Other manuals for Lennox MPA018S4M-*P

Related product manuals