Page 11
Installer
Set−Up
Number
Installer
Set−Up
Name
Selection Description
(Factory setting in bold print)
Notes
0220
Cycles
per Hour
(cph) 1st
Stage
Compres-
sor
3 − Recommended setting for
compressors. Factory setting.
Settings of 1 − 6 cph available.
1 − Recommended for use with steam and
gravity.
Cycles
per Hour
3 − Recommended for use with hot water
heat and high−efficiency (90% or higher)
furnaces.
Shown
only when
0240
5 − Recommended for use with stan-
dard−efficiency (less than 90%) fossil
fuel furnaces. Factory setting.
Heating
9 − Recommended for use with electric
furnaces.
.
Settings of 1 − 12 cph available.
Continu-
0 − Backlight not lit continuously. Back-
light comes on when key is pressed.
Factory setting.
Option
always
shown;
however,
0280
ous
Backlight
1 − Backlight is continuously lit.
(Thermostat must be powered by 24V
common wire for this feature to be
allowed.)
t’stat must
be pow-
ered by
24V com-
mon.
Change-
0 − Manual changeover from heating
mode to cooling mode. Factory setting.
over
1 − Auto−changeover from heating mode to
cooling mode.
3 − 3°F (2°C). Factory setting.
setpoints)
9 − 9°F (5°C)
se
0 − Fahrenheit (factory setting).