Page 12
Installer
Set−Up
Number
Installer
Set−Up
Name
Selection Description
(Factory setting in bold print)
Notes
Daylight
0 − Daylight savings disabled.
Set to 0 in
areas that
do not
0330
D
ay
li
g
ht
Savings
1 − Daylight savings enabled.
Factory setting.
d
o no
t
follow
daylight
savings.
0 − No remote outdoor temperature
sensor. Factory setting.
Defaults
and
options
depend
on system
0340
Remote
Outdoor
Tempera-
ture Sen-
sor
1 − Outdoor temperature sensor used for
display only.
on
system
type
selection.
When set-
ting 0210
is set to 0,
so
2 − Outdoor temperature sensor used to
control heat pump lock−out settings.
is
set
to
0
,
setting
defaults to
2 and
item is not
shown.
0 − Filter change reminder off.
Factory setting.
1 − 10 run time days.
0500
Filter
Ch
2 − 30 run time days.
Run time
based on
0500
Change
Reminder
3 − 60 run time days.
based
on
call for
f
Reminder
4 − 90 run time days.
fan.
5 − 120 run time days.
6 − 365 run time days.
Humidifier
Pad
0 − Humidifier pad replacement remind-
er off. Factory setting.
0510
Pad
Re
p
lace-
1 − 90 run time days.
0510
Replace
ment Re-
minder
2 − 180 run time days.
m
i
n
d
er
3 − 365 run time days.
0520
UV Lamp
Replace-
ment Re
0 − UV lamp replacement reminder off.
Factory setting.
0520
men
t
R
e-
minder
1 − 365 run time days.