Toreplaceasystemfan,dothefollowing:
1.Removetheservercover.See“Removingtheservercoveronpage73.
Note:Thesystemfansarehot-swapandyoucanreplaceafailingsystemfanwithoutturningoff
theserver.
2.Dothefollowingtolocatethefailingsystemfan:
IfyourservercomeswithanIntelligentDiagnosticsModulePremium,youcanviewthesystemfan
errorLEDsonthepanelofthemoduletolocatethefailingsystemfan.See“Diagnosticmodule”
onpage21
.
IfyourserverdoesnotcomewithanIntelligentDiagnosticsModulePremium,youcanviewthe
systemfanerrorLEDsonthesystemboardtolocatethefailingsystemfan.See“Systemboard
LEDs”onpage50.
3.Graspthetopofthesystemfanwithyourindexngerandthumbandthenliftthesystemfanoutof
theserver.
Figure117.Removingthesystemfan
4.Touchthestatic-protectivepackagethatcontainsthenewsystemfantoanyunpaintedsurfaceonthe
outsideoftheserver.Then,removethenewsystemfanfromthepackage.
Chapter6.Installing,removing,orreplacinghardware151