LZV100 Command/Power Station 14
14
6 Configuring the LZV100
There are several settings that can be configured on the LZV100.
These settings can be activated from any XpressNet handheld.
6.1 System Reset
In the rare event that you desire to return the LZV100 to its factory
default condition you can perform a LZV100 Reset.
1) Set your handheld to operate locomotive 00 (the analog
locomotive) and bring that locomotive to a stop
2) Press the F4 key 25 times in succession. You may notice that
after the 20
th
time that a brief power interruption occurs on the
layout.
3) Remove power from the LZV100. When you next power up
the system, all memory will be returned to factory default
settings.
) all memory including knowledge of consists will be removed
from the LZV100 memory when you perform a reset
operation.
6.2 Auto mode/Manual Mode
The LZ10 has two modes of operation. In manual mode (the
default) the LZV100 activates the F0 and F1-F4 functions that
were on when the LZV100 was last shut down. In automatic
operation the speed and direction of all locomotives are also
returned to what they were when the LZV100 was last powered
down.
To reconfigure the LZV100 for automatic operation perform the
following operation.
1) Set your handheld to operate locomotive 00 (the analog
locomotive) and bring that locomotive to a stop
2) Press the F1 key 6 or more times. When next you power up
your LZV100 it will be in automatic mode.
To return the LZV100 to manual operation perform the following
operation.
1) Set your handheld to operate locomotive 00 (the analog
locomotive) and bring that locomotive to a stop
2) Press the F2 key 6 or more times. When next you power up
your LZV100 it will be in manual mode.