EasyManua.ls Logo

Lenze 9400

Lenze 9400
78 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4Technical data
4.2 Protocol data
16
Lenze · E94AYCIB communication module (INTERBUS) · Communication Manual · DMS 4.0 EN · 02/2014 · TD17
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
4.2 Protocol data
4.3 Communication time
The communication time is the time between the start of a request and the arrival of the
corresponding response.
The communication times in an INTERBUS network depend on the ...
processing time in the inverter;
telegram runtime (baud rate / telegram length);
nesting depth of the network.
processing time within the inverter
There are no interdependencies between parameter data and process data.
Range Values
Process data words 0 ... 10 words (16 bits/word)
Parameter data words 0, 1, 2, 4 words (16 bits/word)
The parameter data is transmitted in accordance with the Peripherials
Communication Protocol (PCP).
Supported PMS services Initiate
•Abort
Reject
•Read
•Write
•Get-OD
•Identify
Status
Note!
The data word sum (process data words + parameter data words) has to consist of 1 ... 10
words (16 bits/word).
Data Processing time
Process data Approx. 4 ms
+ 0 ... 1 ms
+ 1 ... x ms
Update cycle
Processing time in the module
Runtime of the application task of the technology
application used (tolerance)
Parameter data Approx. 30 ms + a tolerance of 20 ms (typically)
Some codes may require a longer processing time (see reference manual/
»Engineer« online help for the Servo Drive 9400).