6 Commissioning
6.2 Possible settings via DIP switch
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
6.2.1 Setting the number of process data words
The number of process data words can be set via the switches 1 ... 4.
0 ... 10 process data words can be used.
The current setting is displayed in the »Engineer« in C13860/2
/ C14860/2.
Note!
The data word sum (process data word + parameter data words) has to consist of 1 ... 10
words (16 bits/word).
Impermissible settings are reported by the BE LED (red blinking).
LED status displays
( 47)
The communication module then operates internally with the following values:
2 process data words (PD)
1 parameter data word (PCP)
DIP switch Number of
PD
Switch Max. number
of PCP
1 2 3 4
0 OFF OFF OFF OFF 4
1 OFF OFF OFF ON
2OFFOFFON OFF
3OFFOFFON ON
4OFFON OFF OFF
5OFFON OFF ON
6OFFON ON OFF
7OFFON ON ON 2
8 ON OFF OFF OFF
9 ON OFF OFF ON 1
10 ON OFF ON OFF 0
12345678
ON
OFF

Table of Contents