Lenze · E94AYCIB communication module (INTERBUS) · Communication Manual · DMS 4.0 EN · 02/2014 · TD17 67
13 Parameter reference
13.3 Parameters of the communication module for slot MXI2
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C14862
C14863
C14880
Parameter | Name:
C14862 | Counter
Data type: UNSIGNED_16
Index: 9713 = 0x25F1
Counter for cycles and INTERBUS resets
Display area (min. value | unit | max. value)
0 65535
Subcodes Info
C14862/1 Data cycles per second
C14862/2 Total data cycles
C14862/3 Number of Interbus resets
C14862/4 Number of ID cycles
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C14863 | Active baud rate
Data type: UNSIGNED_8
Index: 9712 = 0x25F0
Display of the set baud rate
Selection list (read only) Info
0 500 kbps
1 2.00 Mbps
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C14880 | Reaction on communication fault
Data type: UNSIGNED_8
Index: 9695 = 0x25DF
Monitoring response in case of a communication fault
A change in the monitoring response becomes immediately effective.
Interruption of the INTERBUS communication
( 45)
Selection list Info
0 No response
1Fault
3 Quick stop by trouble
4 Warning Locked
6 Information
Subcodes Lenze setting Info
C14880/1 0: No Response Response to interrupted INTERBUS communication
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT