Code table
10
Function library
10.20
L
10.20-43
EDS82EV903-1.0-11/2002
Code IMPORTANTPossible settings
No. SelectionLenzeName
C0430* Automatic analog 0
0 not active
Gain and offset are calculated by two points
^ 10.8-3
v
input adjustment
1 Input point for X3/1U, X3/1I
from the setpoint characteristic. Choose
(A)
2 Input points for X3/2U, X3/2I
two points distant from each other to
C0431*
v
(A)
Coordinates point 1 -100.0 {0.1 %} 100.0
.
1. Select and input under C0430 which you
want to calculate gain and offset for
2. Enter point 1 under C0431 X value
1 X(P1) -100.0 Analog setpoint of P1
100 % = max. input value (5 V, 10 V or 20 mA)
(setpoint) and Y value (output frequenc y)
2 Y(P1) -100.0 Output frequency of P1
100 % = C0011
3. Enter point 2 under C0432 X value
(setpoint) and Y value (output frequenc y)
C0432*
v
(A)
Coordinates point 2 -100.0 {0.1 %} 100.0
.
u
v
u
u
y
entered under C0413 (offset) and C0414
(gain)
1 X(P2) 100.0 Analog setpoint of P2
100 % = max. input value (5 V, 10 V or 20 mA)
2 Y(P2) 100.0 Output frequency of P2
100 % = C0011
C0435*
v
(A)
Automatic
frequency input
adjustment
0 0
= not active
{1} 4096 • Only require for speed control with
digital feedback via HTL encoder
• Calculates the gain C0426, depending
on C0425 and C0011
• C0426 will be recalculated aft er ever y
change of C0011 o r C0425.
• Always enter number of increments
divided by number of pole pairs of
the motor!
– Example: Encoder increments = 4096,
motor 4-pole
Þ C0435 = 2048
C0440
(A)
Additional JOG
values
JOG = Setpoint
Activation via configuration under C0410
^ 10.8-13
1 JOG 1 20.00 -650.00 {0.02 Hz} 650.00 C04401/1 and C0037 are the same
2 JOG 2 30.00 C04401/2 and C0038 are the same
3 JOG 3 40.00 C04401/3 and C0039 are the same
4 JOG 4 15.00
5 JOG 5 25.00
6 JOG 6 35.00
7 JOG 7 45.00
C0469*
Function of key
1
0 not active
Determines the function which is activated
s
s of the
eypad
1 CINH (controller inhibit)
when pressing s .
2 QSP (quick stop)
switching!
C0500* Calibration of
numerator variable
2000 1 {1} 25000 • The codes C0010, C0011, C0017,
C0019, C0037, C0038, C0039, C0044,
C0046, C0049, C0050, C0051, C0138,
C0139, C0140, C0181, C0239, C0625,
C0626, C0627 can be calibrated in a
way that the keypad indicates a process
variable.
• If C0500/C0501 remain unchanged, the
unit ”Hz” will no longer be displayed.
^ 10.16-1