Code table
10
Function library
10.20
L
10.20-29
EDS82EV903-1.0-11/2002
Code IMPORTANTPossible settings
No. SelectionLenzeName
C0411
v
Level inversion of
digital inputs
0
0 Level inversion is switched off • By entering the sum of the selected
values you can invert several inputs
• C0114 and C0411 are identical
• The function ”Parameter set
changeover” cannot be inverted!
1 E1 inverted
2 E2 inverted
4 E3 inverted
8 E4 inverted
16 E5 inverted only application I/O
32 E6 inverted only application I/O
64 T1/T2 inverted T1/T2 can only be connected to
potential-free switches.
T1/T2 is active, if the s witch is open.
C0412
v
Free configuration
of analog input
signals
Link between analog signal sources and internal analog
signals
A selection under C0005 or C0007 will
be copied to the corresponding subcode
of C0412. A change of C0412 s ets C0005
= 255, C0007 = 255!
^ 10.12-1
1 Setpoint 1
(NSET1–N1)
1
Analog input 1 (AIN1-OUT):
X3/8 (Standard-I/O)
X3/1U or X3/1I (Application-I/O)
Either NSET1-N1 or
NSET1-N2 active
Change o ver with C0410/17
Parameter
channel:
C0046
2 Setpoint 2
(NSET1-N2)
1
Parameter
channel:
C0044
3 Additional setpoint
(PCTRL1-NADD)
255 Not assigned (FIXED-FREE) or selected via keypad
or parameter channel of an AIF bus module
Is added to NSET1-N1,
NSET1-N2, JOG values and
the function
j of the
keypad
Parameter
channel:
C0049
4 Process controller
setpoint 1
(PCTRL1-SET1)
255 Not assigned (FIXED-FREE) or selected via keypad
or parameter channel of an AIF bus module
5 Act. process
controller value
(PCTRL1-ACT)
255 Not assigned (FIXED-FREE) or selected via keypad
or parameter channel of an AIF bus module
Parameter
channel:
C0051, if
C0238 = 1, 2
6 Torque setpoint or
torque limit value
(MCTRL1-MSET)
255 Not assigned (FIXED-FREE) or selected via keypad
or parameter channel of an AIF bus module
• Obser ve C0014!
• Actual torque values
not required.
• 16384 ≡ 100 % to r que
setpoint
• Condition for selection
via terminal (C0412/6 =
1, 2 or 4):
– The gain of the
analog input is set
to: C0414/x, C0426
= 32768/C0011 [%]
Parameter
channel:
C0047
7 Reserved 255 Not assigned (FIXED-FREE) or selected via keypad
or parameter channel of an AIF bus module
8 MCTRL1-VOLT-ADD 255 Not assigned (FIXED-FREE) or selected via keypad
or parameter channel of an AIF bus module
Only f or special applications. Modifications
only when agreed on by Lenze!
9 MCTRL1-PHI-ADD 255 Not assigned (FIXED-FREE) or selected via keypad
or parameter channel of an AIF bus module