EasyManua.ls Logo

Lenze E94ASHE Series - Residual Hazards

Lenze E94ASHE Series
86 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Safety instructions
Residual hazards
2
51
EDK94SH104 ZH/EN 5.1
2.2 Residual hazards
Protection of persons
ƒ Before working on the controller, check that no voltage is applied to the power
terminals, because
depending on the controller − the power terminals U, V, W, +UG, −UG, Rb1 and Rb2
carry hazardous voltages for up to 3 to 20 minutes after mains disconnection.
the power terminals L1, L2, L3; U, V, W, +UG, −UG, Rb1 and Rb2 carry hazardous
voltages when the motor is stopped.
Device protection
ƒ Plug on or pull off all pluggable terminals only in deenergised condition!
ƒ Cyclically switching on and off of the mains voltage can overload and destroy the
input current limitation of the controller:
In the case of cyclic mains switching for a longer time period, allow at least one
minute between two switch−on actions!
Motor protection
ƒ Depending on the controller settings, the connected motor can be overheated by:
For instance, longer DC−braking operations.
Longer operation of self−ventilated motors at low speed.
Protection of the machine/system
ƒ Drives can reach dangerous overspeeds (e.g. setting of high output frequencies in
connection with motors and machines unsuitable for such conditions):
The controllers do not offer any protection against such operating conditions. Use
additional components for this purpose.

Related product manuals